Literature DB >> 16998660

[Management of complications after angularly stable locking proximal humerus plate fixation].

C Voigt1, A Woltmann, A Partenheimer, H Lill.   

Abstract

PURPOSE: In this prospective study, complications observed after angularly stable proximal humerus plate fixation (locking proximal humerus plate) were analysed by deriving specific therapies. PATIENTS: Fifty patients (median age 65 years, range 25-84 years, 39 female, 11 male) with displaced proximal humerus fractures (seven single, 36 double, and seven triple fractures) were evaluated 3, 6, and 12 months after angularly stable plate fixation using a standard protocol.
RESULTS: Age- and gender-matched median constant scores 12 months postoperatively showed for the three fracture types 86, 87, and 55 points and complication rates of 14, 19, and 100%, respectively. There were seven primary and seven secondary implant displacements, five humeral head necroses, four osseous malalignments, two nonunions, two deep infections, and one heterotopic ossification. Nine reoperations were required in six patients: implant removal (n=3), reosteosynthesis (n=2), revision because of nonunion (n=2), and deep infection (n=2).
CONCLUSIONS: Differentiated analysis of complications and the development of specific prevention and therapeutic strategies considering surgical technique, implant, fracture morphology, and humeral head perfusion minimize the rate of complications observed after angularly stable locking proximal humerus plate fixation.

Entities:  

Mesh:

Year:  2007        PMID: 16998660     DOI: 10.1007/s00104-006-1241-0

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  27 in total

1.  Effect of displacement of fractures of the greater tuberosity on the mechanics of the shoulder.

Authors:  C M Bono; R Renard; R G Levine; A S Levy
Journal:  J Bone Joint Surg Br       Date:  2001-09

Review 2.  [Proximal and distal humerus fractures in advanced age].

Authors:  H Lill; C Josten
Journal:  Orthopade       Date:  2000-04       Impact factor: 1.087

3.  Normalization of the Constant score.

Authors:  Leonid I Katolik; Anthony A Romeo; Brian J Cole; Nikhil N Verma; Jennifer K Hayden; Bernard R Bach
Journal:  J Shoulder Elbow Surg       Date:  2005 May-Jun       Impact factor: 3.019

4.  Biomechanical effects of malposition of tuberosity fragments on the humeral prosthetic reconstruction for four-part proximal humerus fractures.

Authors:  M A Frankle; D P Greenwald; B A Markee; L E Ondrovic; W E Lee
Journal:  J Shoulder Elbow Surg       Date:  2001 Jul-Aug       Impact factor: 3.019

5.  [Locking plate osteosynthesis for fractures of the proximal humerus].

Authors:  W Lungershausen; O Bach; C O Lorenz
Journal:  Zentralbl Chir       Date:  2003-01       Impact factor: 0.942

6.  [The displaced proximal humeral fracture: is there evidence for therapeutic concepts?].

Authors:  M Tingart; H Bäthis; B Bouillon; T Tiling
Journal:  Chirurg       Date:  2001-11       Impact factor: 0.955

7.  [Proximal humeral fracture in the elderly. Primary head replacement as one alternative].

Authors:  A Schittko; A Rüter
Journal:  Chirurg       Date:  2003-11       Impact factor: 0.955

8.  [The angle stable locking-proximal-humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results].

Authors:  H Lill; P Hepp; T Rose; K König; C Josten
Journal:  Zentralbl Chir       Date:  2004-01       Impact factor: 0.942

9.  [Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate].

Authors:  R Hente; J Kampshoff; B Kinner; B Füchtmeier; M Nerlich
Journal:  Unfallchirurg       Date:  2004-09       Impact factor: 1.000

10.  Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year.

Authors:  Jan-Magnus Björkenheim; Jarkko Pajarinen; Vesa Savolainen
Journal:  Acta Orthop Scand       Date:  2004-12
View more
  22 in total

1.  [Technique and value of arthroscopic implant removal in the shoulder].

Authors:  H Lill; C Katthagen; C Voigt
Journal:  Orthopade       Date:  2011-01       Impact factor: 1.087

Review 2.  [Biomechanics of implant augmentation].

Authors:  M Windolf
Journal:  Unfallchirurg       Date:  2015-09       Impact factor: 1.000

3.  Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

Authors:  Ralph Zettl; Thorben Müller; Tobias Topp; Ulrike Lewan; Antonio Krüger; Christian Kühne; Steffen Ruchholtz
Journal:  Int Orthop       Date:  2011-02-08       Impact factor: 3.075

4.  [Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal].

Authors:  J C Katthagen; G Jensen; D Hennecke; H Lill; C Voigt
Journal:  Unfallchirurg       Date:  2012-01       Impact factor: 1.000

5.  Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens.

Authors:  Christine Voigt; Christof Hurschler; Louise Rechi; Rolf Vosshenrich; Helmut Lill
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

6.  [Effect of additive fiber cerclage of the rotator cuff in angle-stable plate-stabilized proximal humeral fractures: a biomechanical study of human shoulder specimens].

Authors:  C Voigt; C Hurschler; J Althainz; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

7.  [Indication for primary fracture prosthesis of the shoulder].

Authors:  C Kirchhoff; P Biberthaler
Journal:  Unfallchirurg       Date:  2013-11       Impact factor: 1.000

8.  [Value of MRI in preoperative diagnostics of proximal humeral fractures compared to CT and conventional radiography].

Authors:  C Voigt; M Ewig; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2010-05       Impact factor: 1.000

9.  [Multiplanar reconstruction with mobile 3D image intensifier. Surgical treatment of proximal humerus fractures].

Authors:  P Hepp; J Theopold; J-S Jarvers; B Marquaß; N von Dercks; C Josten
Journal:  Unfallchirurg       Date:  2014-05       Impact factor: 1.000

10.  Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? A prospective series of 87 patients.

Authors:  Peter Helwig; Christian Bahrs; Björn Epple; Justus Oehm; Christoph Eingartner; Kuno Weise
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.