Literature DB >> 16980688

Dose-guided radiation therapy with megavoltage cone-beam CT.

J Chen1, O Morin, M Aubin, M K Bucci, C F Chuang, J Pouliot.   

Abstract

Recent advances in fractionated external beam radiation therapy have increased our ability to deliver radiation doses that conform more tightly to the tumour volume. The steeper dose gradients delivered in these treatments make it increasingly important to set precisely the positions of the patient and the internal organs. For this reason, considerable research now focuses on methods using three-dimensional images of the patient on the treatment table to adapt either the patient position or the treatment plan, to account for variable organ locations. In this article, we briefly review the different adaptive methods being explored and discuss a proposed dose-guided radiation therapy strategy that adapts the treatment for future fractions to compensate for dosimetric errors from past fractions. The main component of this strategy is a procedure to reconstruct the dose delivered to the patient based on treatment-time portal images and pre-treatment megavoltage cone-beam computed tomography (MV CBCT) images of the patient. We describe the work to date performed to develop our dose reconstruction procedure, including the implementation of a MV CBCT system for clinical use, experiments performed to calibrate MV CBCT for electron density and to use the calibrated MV CBCT for dose calculations, and the dosimetric calibration of the portal imager. We also present an example of a reconstructed patient dose using a preliminary reconstruction program and discuss the technical challenges that remain to full implementation of dose reconstruction and dose-guided therapy.

Entities:  

Mesh:

Year:  2006        PMID: 16980688     DOI: 10.1259/bjr/60612178

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  20 in total

Review 1.  Image-guided radiation therapy for muscle-invasive bladder cancer.

Authors:  Juliette Thariat; Shafak Aluwini; Qiong Pan; Mickael Caullery; Pierre-Yves Marcy; Martin Housset; Jean-Leon Lagrange
Journal:  Nat Rev Urol       Date:  2011-11-08       Impact factor: 14.432

2.  Technical note: DIRART--A software suite for deformable image registration and adaptive radiotherapy research.

Authors:  Deshan Yang; Scott Brame; Issam El Naqa; Apte Aditya; Yu Wu; S Murty Goddu; Sasa Mutic; Joseph O Deasy; Daniel A Low
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

Authors:  Zhong Su; Lisha Zhang; V Ramakrishnan; Michael Hagan; Mitchell Anscher
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

4.  Assessment and evaluation of MV image guidance system performance in radiotherapy.

Authors:  Nithya Kanakavelu; E James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-07

5.  Surface-constrained nonrigid registration for dose monitoring in prostate cancer radiotherapy.

Authors:  Guillaume Cazoulat; Antoine Simon; Aurelien Dumenil; Khemara Gnep; Renaud de Crevoisier; Oscar Acosta; Pascal Haigron
Journal:  IEEE Trans Med Imaging       Date:  2014-04-01       Impact factor: 10.048

6.  Practical Clinical Workflows for Online and Offline Adaptive Radiation Therapy.

Authors:  Olga L Green; Lauren E Henke; Geoffrey D Hugo
Journal:  Semin Radiat Oncol       Date:  2019-07       Impact factor: 5.934

7.  An integrated approach to segmentation and nonrigid registration for application in image-guided pelvic radiotherapy.

Authors:  Chao Lu; Sudhakar Chelikani; Xenophon Papademetris; Jonathan P Knisely; Michael F Milosevic; Zhe Chen; David A Jaffray; Lawrence H Staib; James S Duncan
Journal:  Med Image Anal       Date:  2011-05-20       Impact factor: 8.545

Review 8.  Image-guided radiotherapy: a new dimension in radiation oncology.

Authors:  Florian Sterzing; Rita Engenhart-Cabillic; Michael Flentje; Jürgen Debus
Journal:  Dtsch Arztebl Int       Date:  2011-04-22       Impact factor: 5.594

Review 9.  Mouse models for radiation-induced cancers.

Authors:  Leena Rivina; Michael J Davoren; Robert H Schiestl
Journal:  Mutagenesis       Date:  2016-05-21       Impact factor: 3.000

10.  Stereotactic Body Radiation Therapy (SBRT) Using CyberKnife in Oligometastatic Cancer Patients; Retrospective Evaluation, Single Institution Experience.

Authors:  Abdullah Alsuhaibani; Ahmed Elashwah; Abdullah Alkafi; Camelia Constantinescus; Faisal ALzorkany
Journal:  J Gastrointest Cancer       Date:  2019-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.