Monte Carlo study of a Cyberknife stereotactic radiosurgery system.

Fujio Araki1.   

Abstract

This study investigated small-field dosimetry for a Cyberknife stereotactic radiosurgery system using Monte Carlo simulations. The EGSnrc/BEAMnrc Monte Carlo code was used to simulate the Cyberknife treatment head, and the DOSXYZnrc code was implemented to calculate central axis depth-dose curves, off-axis dose profiles, and relative output factors for various circular collimator sizes of 5 to 60 mm. Water-to-air stopping power ratios necessary for clinical reference dosimetry of the Cyberknife system were also evaluated by Monte Carlo simulations. Additionally, a beam quality conversion factor, kQ, for the Cyberknife system was evaluated for cylindrical ion chambers with different wall material. The accuracy of the simulated beam was validated by agreement within 2% between the Monte Carlo calculated and measured central axis depth-dose curves and off-axis dose profiles. The calculated output factors were compared with those measured by a diode detector and an ion chamber in water. The diode output factors agreed within 1% with the calculated values down to a 10 mm collimator. The output factors with the ion chamber decreased rapidly for collimators below 20 mm. These results were confirmed by the comparison to those from Monte Carlo methods with voxel sizes and materials corresponding to both detectors. It was demonstrated that the discrepancy in the 5 and 7.5 mm collimators for the diode detector is due to the water non-equivalence of the silicon material, and the dose fall-off for the ion chamber is due to its large active volume against collimators below 20 mm. The calculated stopping power ratios of the 60 mm collimator from the Cyberknife system (without a flattening filter) agreed within 0.2% with those of a 10 X 10 cm2 field from a conventional linear accelerator with a heavy flattening filter and the incident electron energy, 6 MeV. The difference in the stopping power ratios between 5 and 60 mm collimators was within 0.5% at a 10 cm depth in water. Furthermore, kQ values for the Cyberknife system were in agreement within 0.3% with those of the conventional 6 MV-linear accelerator for the cylindrical ion chambers with different wall material.

Entities:  

Mesh:

Year:  2006        PMID: 16964874     DOI: 10.1118/1.2219774

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

Review 2.  Stereotactic radiosurgery alone for multiple brain metastases? A review of clinical and technical issues.

Authors:  Arjun Sahgal; Mark Ruschin; Lijun Ma; Wilko Verbakel; David Larson; Paul D Brown
Journal:  Neuro Oncol       Date:  2017-04-01       Impact factor: 12.300

3.  Polarity effect in commercial ionization chambers used in photon beams with small fields.

Authors:  Tetsunori Shimono; Kichiro Koshida; Hidekazu Nambu; Kosuke Matsubara; Hiroshi Takahashi; Hiroshi Okuda
Journal:  Radiol Phys Technol       Date:  2008-12-18

4.  Variation of kQclin,Qmsr (fclin,fmsr) for the small-field dosimetric parameters percentage depth dose, tissue-maximum ratio, and off-axis ratio.

Authors:  Paolo Francescon; Sam Beddar; Ninfa Satariano; Indra J Das
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

5.  Determination of inflection points of CyberKnife dose profiles within acceptability criteria of deviations in measurements.

Authors:  Neslihan Sarıgül; Fazlı Yağız Yedekçi; Mete Yeğiner; Fadıl Akyol; Haluk Utku
Journal:  Rep Pract Oncol Radiother       Date:  2019-11-12

6.  The effect of MLC leaf width in single-isocenter multi-target radiosurgery with volumetric modulated arc therapy.

Authors:  Zhanerke Abisheva; Scott R Floyd; Joseph K Salama; John Kirkpatrick; Fang-Fang Yin; Michael J Moravan; William Giles; Justus Adamson
Journal:  J Radiosurg SBRT       Date:  2019

7.  Effectiveness of the Monte Carlo method in stereotactic radiation therapy applied to quasi-homogenous brain tumors.

Authors:  Ki Mun Kang; Bae Kwon Jeong; Hoon Sik Choi; Jin Ho Song; Byung-Do Park; Young Kyung Lim; Hojin Jeong
Journal:  Oncotarget       Date:  2016-03-15

8.  Development of a dose verification system for Vero4DRT using Monte Carlo method.

Authors:  Yoshitomo Ishihara; Akira Sawada; Mitsuhiro Nakamura; Yuki Miyabe; Hiroaki Tanabe; Shuji Kaneko; Kenji Takayama; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

9.  Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification.

Authors:  Shih-Ming Hsu; Chao-Hsiung Hung; Yi-Jen Liao; Hsiao-Mei Fu; Jo-Ting Tsai; Yung-Hui Huang; David Y C Huang
Journal:  PLoS One       Date:  2017-01-03       Impact factor: 3.240

10.  Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system.

Authors:  Jason Y Cheng; Holly Ning; Barbara C Arora; Ying Zhuge; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.