Measurement of energy dependence for XRCT radiochromic film.

Martin J Butson1, Tsang Cheung, Peter K N Yu.   

Abstract

Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 kVp) peaking at 12.1 +/- 0.5 at 54 keV (125 kVp) to 0.975 +/- 0.03 at 2300 keV (10 MV) when normalized to 1 at 1400 keV (6 MV) energy. The response is constant (within 3%) in the 36-69 keV equivalent photon energy range, which corresponds to x-ray tube generating potentials of approximately 100-150 kVp. This matches well with beam qualities for diagnostic computed topography applications.

Entities:  

Mesh:

Year:  2006        PMID: 16964870     DOI: 10.1118/1.2219330

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Experimental estimates of peak skin dose and its relationship to the CT dose index using the CTDI head phantom.

Authors:  Hugo de las Heras; Ronaldo Minniti; Sean Wilson; Chad Mitchell; Marlene Skopec; Claudia C Brunner; Kish Chakrabarti
Journal:  Radiat Prot Dosimetry       Date:  2013-07-16       Impact factor: 0.972

2.  Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

Authors:  Dominic J Crotty; Samuel L Brady; D'Vone C Jackson; Greta I Toncheva; Colin E Anderson; Terry T Yoshizumi; Martin P Tornai
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

3.  Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography.

Authors:  A Al-Okshi; M Nilsson; A Petersson; M Wiese; C Lindh
Journal:  Dentomaxillofac Radiol       Date:  2013-04-22       Impact factor: 2.419

4.  Suitability of radiochromic films for dosimetry of very-low energy X-rays.

Authors:  Martin A Ebert; Ali H Asad; Salim A Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

5.  Calibration of the EBT3 Gafchromic Film Using HNN Deep Learning.

Authors:  Liyun Chang; Shyh-An Yeh; Sheng-Yow Ho; Hueisch-Jy Ding; Pang-Yu Chen; Tsair-Fwu Lee
Journal:  Biomed Res Int       Date:  2021-01-31       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.