Literature DB >> 16953944

Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter.

G Gueret1, G Kiss, B Rossignol, E Bezon, J P Wargnier, A Miossec, O Corre, C C Arvieux.   

Abstract

BACKGROUND: The aim of this prospective study was to compare continuous cardiac output measurements of the non-invasive cardiac output system (NICO) with the pulmonary artery catheter during off-pump coronary bypass surgery.
METHODS: Twenty-two patients enrolled for off-pump coronary surgery received both a pulmonary artery catheter and a non-invasive cardiac output system for measurement of cardiac output. Data were compared by the Bland-Altman method to calculate the degree of agreement and to analyse if a significant difference existed between the two methods of cardiac output measurements.
RESULTS: Perioperatively, the non-invasive cardiac output underestimated cardiac output, but postoperatively overestimated it. The limits of agreement were larger during surgery compared to the postoperative period (-3.1; +2.5 vs. -1.4; +2.2 L min(-1)). Perioperatively, cardiac output measured with the pulmonary artery catheter varied from 0.5 to 7.5 L min(-1) (mean 3.6 L min(-1)) and with the non-invasive cardiac output from 0.5 to 8.4 L min(-1) (mean 3.9 L min(-1)). Postoperatively, these were 2.5-7.7 L min(-1) (mean 4.5 L min(-1)) and 2.3-8.4 L min(-1) (mean 4.9 L min(-1)), respectively.
CONCLUSION: During off-pump cardiac surgery, the non-invasive cardiac output reliably measures cardiac output and does it more rapidly than a pulmonary artery catheter and may be more useful in order to detect rapid haemodynamic changes.

Entities:  

Mesh:

Year:  2006        PMID: 16953944     DOI: 10.1017/S0265021506000573

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  9 in total

Review 1.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

Review 2.  Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Giorgio della Rocca; Maxime Cannesson; Christoph K Hofer
Journal:  Curr Heart Fail Rep       Date:  2010-09

Review 3.  Newer methods of cardiac output monitoring.

Authors:  Yatin Mehta; Dheeraj Arora
Journal:  World J Cardiol       Date:  2014-09-26

Review 4.  Minimally invasive or noninvasive cardiac output measurement: an update.

Authors:  Lisa Sangkum; Geoffrey L Liu; Ling Yu; Hong Yan; Alan D Kaye; Henry Liu
Journal:  J Anesth       Date:  2016-03-09       Impact factor: 2.078

5.  Higher pulmonary dead space may predict prolonged mechanical ventilation after cardiac surgery.

Authors:  Thida Ong; Regan B Stuart-Killion; Brian M Daniel; Laura B Presnell; Hanjing Zhuo; Michael A Matthay; Kathleen D Liu
Journal:  Pediatr Pulmonol       Date:  2009-05

6.  Cardiac output assessed by invasive and minimally invasive techniques.

Authors:  Allison J Lee; Jennifer Hochman Cohn; J Sudharma Ranasinghe
Journal:  Anesthesiol Res Pract       Date:  2011-07-06

Review 7.  Cardiac output monitoring: an integrative perspective.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Christoph K Hofer
Journal:  Crit Care       Date:  2011-03-22       Impact factor: 9.097

Review 8.  Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12.

Authors:  Jean-Louis Vincent; Paolo Pelosi; Rupert Pearse; Didier Payen; Azriel Perel; Andreas Hoeft; Stefano Romagnoli; V Marco Ranieri; Carole Ichai; Patrice Forget; Giorgio Della Rocca; Andrew Rhodes
Journal:  Crit Care       Date:  2015-05-08       Impact factor: 9.097

Review 9.  Cardiac output monitoring: Technology and choice.

Authors:  Jeff Kobe; Nitasha Mishra; Virendra K Arya; Waiel Al-Moustadi; Wayne Nates; Bhupesh Kumar
Journal:  Ann Card Anaesth       Date:  2019 Jan-Mar
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.