Literature DB >> 16946746

Intraocular pressure measurement in mice: a comparison between Goldmann and rebound tonometry.

C Y Kim1, M H Kuehn, M G Anderson, Y H Kwon.   

Abstract

PURPOSE: The development of mouse models of glaucoma requires methods to accurately measure the intraocular pressure (IOP) in this species. The aim of this study was to compare the accuracy of IOP measurements in mice between modified Goldmann and rebound tonometers.
METHODS: IOP was measured either with a modified Goldmann or a rebound tonometer while simultaneously measuring the IOP using invasive manometry in enucleated eyes and in vivo. The level of IOP was controlled hydrostatically. The agreement and correlation between the IOP determined by invasive manometry and by either noninvasive method was evaluated. In addition, the IOP was determined by both noninvasive methods in a cohort of mice with laser-induced ocular hypertension (OHT), and the agreement and correlation between the two tonometry methods were evaluated.
RESULTS: Measured IOP by either noninvasive tonometer correlated well with those recorded simultaneously by invasive manometry (r=0.98 for rebound and r=0.94 for Goldmann). In mice with OHT, the IOP correlation between rebound and modified Goldmann was moderate (r=0.71); the IOP measured by modified Goldmann tonometry was consistently higher than that by rebound by approximately 5 mmHg. However, the relative per cent increases in IOP were similar between the two methods.
CONCLUSION: Both noninvasive methods of IOP measurements in mice are suitable to detect changes in IOP although rebound tonometry correlated better with the invasive manometry readings. The results suggest that the relative, rather than absolute, IOP offers a more reliable means of correlating findings from studies using different tonometers.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16946746     DOI: 10.1038/sj.eye.6702576

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  24 in total

1.  Calibration of the TonoLab tonometer in mice with spontaneous or experimental glaucoma.

Authors:  Mary E Pease; Frances E Cone; Scott Gelman; Janice L Son; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-22       Impact factor: 4.799

2.  Transplantation of iPSC-derived TM cells rescues glaucoma phenotypes in vivo.

Authors:  Wei Zhu; Oliver W Gramlich; Lauren Laboissonniere; Ankur Jain; Val C Sheffield; Jeffrey M Trimarchi; Budd A Tucker; Markus H Kuehn
Journal:  Proc Natl Acad Sci U S A       Date:  2016-06-06       Impact factor: 11.205

3.  Reliability of Tonolab measurements in rats.

Authors:  Li-Fang Liu; Chu-Kai Huang; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2014-12-18       Impact factor: 1.779

4.  Lack of immunoglobulins does not prevent C1q binding to RGC and does not alter the progression of experimental glaucoma.

Authors:  Qiong J Ding; Amy C Cook; Alina V Dumitrescu; Markus H Kuehn
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-09-19       Impact factor: 4.799

5.  Central corneal thickness does not correlate with TonoLab-measured IOP in several mouse strains with single transgenic mutations of matricellular proteins.

Authors:  Ayan Chatterjee; Dong-Jin Oh; Min Hyung Kang; Douglas J Rhee
Journal:  Exp Eye Res       Date:  2013-06-24       Impact factor: 3.467

6.  Reduction of ER stress via a chemical chaperone prevents disease phenotypes in a mouse model of primary open angle glaucoma.

Authors:  Gulab S Zode; Markus H Kuehn; Darryl Y Nishimura; Charles C Searby; Kabhilan Mohan; Sinisa D Grozdanic; Kevin Bugge; Michael G Anderson; Abbot F Clark; Edwin M Stone; Val C Sheffield
Journal:  J Clin Invest       Date:  2011-08-08       Impact factor: 14.808

7.  Evaluation of rebound tonometry in non-human primates.

Authors:  Elizabeth J Elsmo; Julie A Kiland; Paul L Kaufman; Gillian J McLellan
Journal:  Exp Eye Res       Date:  2011-02-16       Impact factor: 3.467

8.  Intraocular pressure with rebound tonometry and effects of topical intraocular pressure reducing medications in guinea pigs.

Authors:  Yue Di; Xiu-Mei Luo; Tong Qiao; Na Lu
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

9.  Gremlin Induces Ocular Hypertension in Mice Through Smad3-Dependent Signaling.

Authors:  Colleen M McDowell; Humberto Hernandez; Weiming Mao; Abbot F Clark
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-08       Impact factor: 4.799

10.  Lyst mutation in mice recapitulates iris defects of human exfoliation syndrome.

Authors:  Colleen M Trantow; Mao Mao; Greg E Petersen; Erin M Alward; Wallace L M Alward; John H Fingert; Michael G Anderson
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-11-21       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.