A two-dimensional, finite element analysis of vasogenic brain edema.

T Nagashima1, T Shirakuni, S I Rapoport.   

Abstract

The authors constructed a two-dimensional model of vasogenic brain edema, using the finite element method (FEM). The model incorporates the following physical parameters: cerebrovascular hydraulic conductivity, metabolic water production, tissue hydraulic conductivity and compliance, tissue and plasma osmotic and hydrostatic pressures, cerebrospinal fluid hydrostatic pressure and absorption, intracerebral stress, and shift of brain tissue. These parameters, related by partial differential equations, were approximated numerically in time and space by the FEM. The results of computer simulation of brain edema by the FEM were compared with experimental data obtained in a feline cold injury brain edema model. Computer simulation predicted the changes observed in interstitial pressure, extent of edema, intracerebral stress distribution, and shift of brain tissue. The results indicate that the FEM, applied to a model of vasogenic brain edema, can be used to predict the time course and regional distribution of fluid accumulation and the accompanying regional stress and deformation of brain tissue.

Entities:  

Mesh:

Year:  1990        PMID: 1694266     DOI: 10.2176/nmc.30.1

Source DB:  PubMed          Journal:  Neurol Med Chir (Tokyo)        ISSN: 0470-8105            Impact factor:   1.742


  19 in total

1.  Contrast detection in fluid-saturated media with magnetic resonance poroelastography.

Authors:  Phillip R Perriñez; Adam J Pattison; Francis E Kennedy; John B Weaver; Keith D Paulsen
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

2.  Model-Updated Image Guidance: A Statistical Approach to Gravity-Induced Brain Shift.

Authors:  Prashanth Dumpuri; Michael I Miga
Journal:  Med Image Comput Comput Assist Interv       Date:  2003-11

3.  Initial In-Vivo Analysis of 3D Heterogeneous Brain Computations for Model-Updated Image-Guided Neurosurgery.

Authors:  Michael Miga; Keith Paulsen; Francis Kennedy; Jack Hoopes; Alex Hartov; David Roberts
Journal:  Med Image Comput Comput Assist Interv       Date:  1998-10

4.  An atlas-based method to compensate for brain shift: preliminary results.

Authors:  Prashanth Dumpuri; Reid C Thompson; Benoit M Dawant; A Cao; Michael I Miga
Journal:  Med Image Anal       Date:  2007-03-01       Impact factor: 8.545

5.  Magnetic resonance elastography of the brain.

Authors:  Scott A Kruse; Gregory H Rose; Kevin J Glaser; Armando Manduca; Joel P Felmlee; Clifford R Jack; Richard L Ehman
Journal:  Neuroimage       Date:  2007-08-29       Impact factor: 6.556

Review 6.  Magnetic resonance elastography: a general overview of its current and future applications in brain imaging.

Authors:  Antonio Di Ieva; Fabio Grizzi; Elisa Rognone; Zion Tsz Ho Tse; Tassanai Parittotokkaporn; Ferdinando Rodriguez Y Baena; Manfred Tschabitscher; Christian Matula; Siegfrid Trattnig; Riccardo Rodriguez Y Baena
Journal:  Neurosurg Rev       Date:  2010-02-27       Impact factor: 3.042

7.  In vivo modeling of interstitial pressure in a porcine model: approximation of poroelastic properties and effects of enhanced anatomical structure modeling.

Authors:  Saramati Narasimhan; Jared A Weis; Hernán F J González; Reid C Thompson; Michael I Miga
Journal:  J Med Imaging (Bellingham)       Date:  2018-12-06

8.  Is the Donnan effect sufficient to explain swelling in brain tissue slices?

Authors:  Georgina E Lang; Peter S Stewart; Dominic Vella; Sarah L Waters; Alain Goriely
Journal:  J R Soc Interface       Date:  2014-04-23       Impact factor: 4.118

9.  Near Real-Time Computer Assisted Surgery for Brain Shift Correction Using Biomechanical Models.

Authors:  Kay Sun; Thomas S Pheiffer; Amber L Simpson; Jared A Weis; Reid C Thompson; Michael I Miga
Journal:  IEEE J Transl Eng Health Med       Date:  2014-04-30       Impact factor: 3.316

10.  Modeling of soft poroelastic tissue in time-harmonic MR elastography.

Authors:  Phillip R Perriñez; Francis E Kennedy; Elijah E W Van Houten; John B Weaver; Keith D Paulsen
Journal:  IEEE Trans Biomed Eng       Date:  2008-12-02       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.