Literature DB >> 16937211

Electronic root canal length measurement before and after experimentally induced pulpitis and apical periodontitis in dogs.

Maja Kovacevic1, Tomislav Tamarut, Snjezana Glavicić, Nives Jonjic, Sanja Zoricić-Cvek, Dragica Bobinac.   

Abstract

The aim of the study was to examine the influence of the state of the pulp and apical periodontium on the results of electronic root canal length measurement (ERCLM) with a resistance measuring device in dogs. Pulpitis and apical periodontitis were induced by pulp exposure and contamination by the oral flora in the premolar teeth of six mongrel dogs, comprising four experimental groups (36 root canals). In a control group, measured lengths of teeth with uninfected pulps were performed on the first experimental day (44 root canals). In all animals the ERCLMs were performed on teeth with healthy pulps, and at the end of the experimental period (20, 35, 50 and 65 days) following pulp exposure. The point of measuring canal lengths was the anatomical obstacle above the apical delta. Electronically measured lengths (EML) were compared between each other and with the root canal length established by tactile-sense measurement verified radiographically. The EMLs were less accurate in teeth with healthy pulps and teeth with pulpitis in the third experimental group (dif=2.27 x 2.65 mm(2); t test, p<0.05), while they were most precise after 65 days in teeth with completely necrotic pulp and established chronic apical periodontitis (dif=0.54 x 1.36 mm(2); t test, p>0.05). These results suggest that the state of the pulp and periapical tissue may have an influence on the ERCLM.

Entities:  

Mesh:

Year:  2006        PMID: 16937211     DOI: 10.1007/s11517-006-0076-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

1.  Accuracy of a new apex locator: an in vitro study.

Authors:  A Y Kaufman; S Keila; M Yoshpe
Journal:  Int Endod J       Date:  2002-02       Impact factor: 5.264

2.  The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files.

Authors:  Anthony S Thomas; Gary R Hartwell; Peter C Moon
Journal:  J Endod       Date:  2003-10       Impact factor: 4.171

3.  Clinical accuracy of a new apex locator with an automatic compensation circuit.

Authors:  Seung Jong Lee; Ki Chang Nam; Young-Joo Kim; Deok Won Kim
Journal:  J Endod       Date:  2002-10       Impact factor: 4.171

4.  Variables affecting electronic root canal measurement.

Authors:  Y N Wu; J N Shi; L Z Huang; Y Y Xu
Journal:  Int Endod J       Date:  1992-03       Impact factor: 5.264

5.  Influence of the major and minor foramen diameters on apical electronic probe measurements.

Authors:  T J Stein; J F Corcoran; R M Zillich
Journal:  J Endod       Date:  1990-11       Impact factor: 4.171

6.  [Correlation of endometric results with the conditions in the root canal].

Authors:  D Pahncke; A Voss
Journal:  Dtsch Zahnarztl Z       Date:  1991-09

7.  Electronic ohmmeter. An electronic device for the determination of the root canal length.

Authors:  R V Suchde; S T Talim
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1977-01

8.  [Qualitative changes of the pulp and multiple electric measurement of the canal].

Authors:  T Tamarut; N Cindrić; B Medugorac
Journal:  Acta Stomatol Croat       Date:  1988

9.  Clinical evaluation of an electronic root canal measuring device.

Authors:  P V Abbott
Journal:  Aust Dent J       Date:  1987-02       Impact factor: 2.291

10.  Influence of the concentration of ions and foramen diameter on the accuracy of electronic root canal length measurement--an experimental study.

Authors:  M Kovacević; T Tamarut
Journal:  J Endod       Date:  1998-05       Impact factor: 4.171

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.