AIMS: Non-invasive assessment of left ventricular (LV) structure and function is important in the evaluation of cardiac patients. This study was designed to test the accuracy and reproducibility of new generation 3-dimensional echocardiography (3DE) in measuring volumetric and functional LV indices as compared with current "gold standard" of non-invasive cardiac imaging, cardiac magnetic resonance (CMR). METHODS AND RESULTS: Sixty-four subjects with good acoustic windows, including 40 cardiac patients with LV ejection fraction (EF)<45%, 14 patients with EF>45% and 10 normal volunteers underwent 3DE using a commercially available Philips Sonos 7500 scanner equipped with a matrix phase-array x4 xMATRIX transducer, and CMR on a 1.5 T Signa CV/i scanner (GE Medical Systems). Volumetric assessment was performed with analytical 4D-LV-Analysis software (TomTec) for 3DE and MRI-Mass software (Medis) for CMR. We found no significant differences in LV end-diastolic volume (EDV), end-systolic volume (ESV) and EF with excellent correlations between the indices measured using 3DE and CMR (r=0.97, r=0.98, and r=0.94, respectively). Bland-Altman analysis showed bias of 7 ml for EDV, 3 ml for ESV and -1% for EF with 3DE with corresponding limits of agreement (2SD) of 28 ml, 22 ml and 10%, respectively. Intraobserver and interobserver variabilities were for EDV: 3% and 4% (3DE) vs 2% and 2% (CMR), for ESV: 3% and 6% (3DE) vs 2% and 3% (CMR), and for EF: 4% and 4% (3DE) vs 2% and 4% (CMR), respectively. CONCLUSION: New generation 3DE provides accurate and reproducible quantification of LV volumetric and functional data in subjects with good acoustic windows as compared with CMR.
AIMS: Non-invasive assessment of left ventricular (LV) structure and function is important in the evaluation of cardiac patients. This study was designed to test the accuracy and reproducibility of new generation 3-dimensional echocardiography (3DE) in measuring volumetric and functional LV indices as compared with current "gold standard" of non-invasive cardiac imaging, cardiac magnetic resonance (CMR). METHODS AND RESULTS: Sixty-four subjects with good acoustic windows, including 40 cardiac patients with LV ejection fraction (EF)<45%, 14 patients with EF>45% and 10 normal volunteers underwent 3DE using a commercially available Philips Sonos 7500 scanner equipped with a matrix phase-array x4 xMATRIX transducer, and CMR on a 1.5 T Signa CV/i scanner (GE Medical Systems). Volumetric assessment was performed with analytical 4D-LV-Analysis software (TomTec) for 3DE and MRI-Mass software (Medis) for CMR. We found no significant differences in LV end-diastolic volume (EDV), end-systolic volume (ESV) and EF with excellent correlations between the indices measured using 3DE and CMR (r=0.97, r=0.98, and r=0.94, respectively). Bland-Altman analysis showed bias of 7 ml for EDV, 3 ml for ESV and -1% for EF with 3DE with corresponding limits of agreement (2SD) of 28 ml, 22 ml and 10%, respectively. Intraobserver and interobserver variabilities were for EDV: 3% and 4% (3DE) vs 2% and 2% (CMR), for ESV: 3% and 6% (3DE) vs 2% and 3% (CMR), and for EF: 4% and 4% (3DE) vs 2% and 4% (CMR), respectively. CONCLUSION: New generation 3DE provides accurate and reproducible quantification of LV volumetric and functional data in subjects with good acoustic windows as compared with CMR.
Authors: Nina Ajmone Marsan; Maureen M Henneman; Ji Chen; Claudia Ypenburg; Petra Dibbets; Stefano Ghio; Gabe B Bleeker; Marcel P Stokkel; Ernst E van der Wall; Luigi Tavazzi; Ernest V Garcia; Jeroen J Bax Journal: J Am Soc Echocardiogr Date: 2008-01-28 Impact factor: 5.251
Authors: Jimmy C Lu; Gregory J Ensing; Sunkyung Yu; Thor Thorsson; Janet E Donohue; Adam L Dorfman Journal: Pediatr Cardiol Date: 2012-07-14 Impact factor: 1.655
Authors: Bernard Cosyns; David Haberman; Steven Droogmans; Sandrine Warzée; Philippe Mahieu; Eric Laurent; Marie Moonen; Sophie Hernot; Patrizio Lancellotti Journal: Cardiovasc Ultrasound Date: 2009-06-16 Impact factor: 2.062