Literature DB >> 16905760

Japanese adult male voxel phantom constructed on the basis of CT images.

K Sato1, H Noguchi, Y Emoto, S Koga, K Saito.   

Abstract

A Japanese adult male voxel (volume pixel) phantom (hereinafter referred to as the JM phantom) was constructed on the basis of CT images of a healthy Japanese adult male volunteer. Body characteristics of the JM phantom were compared with those of a voxelised MIRD5 type phantom and a Japanese adult male voxel phantom which was previously developed. The voxel size of the JM phantom is 0.98 x 0.98 x 1 mm(3). The shapes of the organs of the JM phantom, even for small or complicated organs, such as thyroid and stomach, are more realistically reproduced as compared with the previous Japanese voxel phantom (voxel size: 0.98 x 0.98 x 10 mm(3)). Photon self-absorbed fractions (self-AFs) for brain, kidneys, spleen, pancreas, thyroid and urinary bladder wall of JM were evaluated and were compared with those of the other phantoms. In consequence, it was suggested that the mass, shape and thickness of organs are important factors for the determination of self-AFs.

Entities:  

Mesh:

Year:  2006        PMID: 16905760     DOI: 10.1093/rpd/ncl101

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

Review 1.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

2.  A study of predicted bone marrow distribution on calculated marrow dose from external radiation exposures using two sets of image data for the same individual.

Authors:  Peter F Caracappa; T C Ephraim Chao; X George Xu
Journal:  Health Phys       Date:  2009-06       Impact factor: 1.316

3.  MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck.

Authors:  Maria Ida Iacono; Esra Neufeld; Esther Akinnagbe; Kelsey Bower; Johanna Wolf; Ioannis Vogiatzis Oikonomidis; Deepika Sharma; Bryn Lloyd; Bertram J Wilm; Michael Wyss; Klaas P Pruessmann; Andras Jakab; Nikos Makris; Ethan D Cohen; Niels Kuster; Wolfgang Kainz; Leonardo M Angelone
Journal:  PLoS One       Date:  2015-04-22       Impact factor: 3.240

4.  Fast skin dose estimation system for interventional radiology.

Authors:  Takeshi Takata; Jun'ichi Kotoku; Hideyuki Maejima; Shinobu Kumagai; Norikazu Arai; Takenori Kobayashi; Kenshiro Shiraishi; Masayoshi Yamamoto; Hiroshi Kondo; Shigeru Furui
Journal:  J Radiat Res       Date:  2018-03-01       Impact factor: 2.724

5.  Construction of Taiwanese Adult Reference Phantoms for Internal Dose Evaluation.

Authors:  Shu-Jun Chang; Shih-Yen Hung; Yan-Lin Liu; Shiang-Huei Jiang
Journal:  PLoS One       Date:  2016-09-12       Impact factor: 3.240

  5 in total