Literature DB >> 16895727

Minimally invasive locking plate osteosynthesis for fractures of the distal tibia--results in 20 patients.

S Hazarika1, J Chakravarthy, J Cooper.   

Abstract

AIMS: We report our experiences with minimally invasive locking plate osteosynthesis (MILPO), for distal tibia fractures, with specific reference to fracture union and complications encountered. PATIENTS AND METHODS: Twenty patients underwent MILPO for open and closed distal tibia fractures between March 2003 and December 2004. Fractures were classified according to the AO system. Open fractures were graded using the Gustilo and Anderson classification and closed fractures via the Tscherne classification system.
RESULTS: There were 16 males and 4 females of mean age 44.7 years (range 19-69 years). Thirteen patients had temporary external fixation, prior to definitive fracture fixation. Minimum follow-up was 12 months and average time to full weight bearing in the closed fracture group (12 patients) was 18.1 weeks (range 8-32 weeks) and 19.3 weeks in the open fracture group (8 patients, range 8-44 weeks). Fracture healing was defined as radiological evidence of bridging mature callus combined with pain-free full weight bearing. In the open fracture group, four fractures united within 6 months, one within 6-12 months and one united 12 months after surgery; there were two cases of non-union. In the closed fracture group, seven fractures united within 6 months, three fractures between 6 and 12 months and two after 12 months from surgery. Two of the 20 patients required additional procedures to aid bone healing in the post-operative period. Three of the 20 patients required metalwork removal, for delayed wound breakdown in two cases and wound infection in one case. An uneventful recovery was made following this, in all three cases. There was one case of implant failure due to plate breakage at 32 weeks post-op. The fracture site was opened and re-plated at 32 weeks with a DCP. There were no complications following this.
CONCLUSION: MILPO was used for definitive fixation of high energy, open and closed, peri-articular distal tibia fractures. This approach aims to preserve bone biology and minimise surgical soft tissue trauma. This surgical approach may provide an answer to treating a challenging group of fractures and further research is warranted.

Entities:  

Mesh:

Year:  2006        PMID: 16895727     DOI: 10.1016/j.injury.2006.06.002

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  33 in total

1.  Injury characteristics and management of orthopaedic trauma in refugee children.

Authors:  Alkan Bayrak; Vedat Öztürk; Alican Koluman; Nezih Ziroğlu; Altuğ Duramaz
Journal:  Int Orthop       Date:  2021-01-23       Impact factor: 3.075

2.  Intramedullary nailing versus percutaneous locked plating of distal extra-articular tibial fractures: a retrospective study.

Authors:  Mustafa Seyhan; Koray Unay; Nadir Sener
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-05-29

3.  Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients.

Authors:  Rafiq Bhat; Mubashir Maqbool Wani; Shakir Rashid; Nahida Akhter
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-20

4.  The service impact of failed locking plate fixation of distal tibial fractures: a service and financial evaluation at a major trauma centre.

Authors:  Michael Kent; Aadil Mumith; Jo McEwan; Nicholas Hancock
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-10-01

5.  Treatment of distal tibial shaft fractures by three different surgical methods: a randomized, prospective study.

Authors:  Yongchuan Li; Xi Jiang; Qinghe Guo; Lei Zhu; Tianwen Ye; Aimin Chen
Journal:  Int Orthop       Date:  2014-02-19       Impact factor: 3.075

6.  Minimally Invasive Plate Osteosynthesis with Locking Plates for Distal Tibia Fractures.

Authors:  Ajeet Dhakar; Rajendra Annappa; Mahesh Gupta; Hemeshwar Harshwardhan; Prem Kotian; Pooja K Suresh
Journal:  J Clin Diagn Res       Date:  2016-03-01

7.  Management of distal third tibial fractures: comparison of combined internal and external fixation with minimally invasive percutaneous plate osteosynthesis.

Authors:  Liao-Jun Sun; Zhi-Peng Wu; Xiao-Shan Guo; Hua Chen
Journal:  Int Orthop       Date:  2014-08-03       Impact factor: 3.075

8.  Minimally invasive locked plating of distal tibia fractures is safe and effective.

Authors:  Mario Ronga; Umile Giuseppe Longo; Nicola Maffulli
Journal:  Clin Orthop Relat Res       Date:  2009-07-30       Impact factor: 4.176

9.  Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

Authors:  Rakesh K Gupta; Rajesh Kumar Rohilla; Kapil Sangwan; Vijendra Singh; Saurav Walia
Journal:  Int Orthop       Date:  2009-10-10       Impact factor: 3.075

10.  Minimally invasive medial plate osteosynthesis in tibial pilon fractures: Longterm functional and radiological outcomes.

Authors:  Alican Barış; Esra Çirci; Ziya Demirci; Yusuf Öztürkmen
Journal:  Acta Orthop Traumatol Turc       Date:  2020-01       Impact factor: 1.511

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.