Literature DB >> 19641974

Minimally invasive locked plating of distal tibia fractures is safe and effective.

Mario Ronga1, Umile Giuseppe Longo, Nicola Maffulli.   

Abstract

UNLABELLED: Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2009        PMID: 19641974      PMCID: PMC2835592          DOI: 10.1007/s11999-009-0991-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  44 in total

1.  Percutaneous plate fixation of fractures of the distal tibia.

Authors:  Jens Francois; Geoffroy Vandeputte; Frank Verheyden; Guy Nelen
Journal:  Acta Orthop Belg       Date:  2004-04       Impact factor: 0.500

2.  Pylon fractures of the distal tibia.

Authors:  R B Bourne
Journal:  Clin Orthop Relat Res       Date:  1989-03       Impact factor: 4.176

3.  Pilon fractures. Treatment protocol based on severity of soft tissue injury.

Authors:  J T Watson; B R Moed; D E Karges; K E Cramer
Journal:  Clin Orthop Relat Res       Date:  2000-06       Impact factor: 4.176

4.  Minimally invasive plate osteosynthesis of distal fractures of the tibia.

Authors:  D L Helfet; P Y Shonnard; D Levine; J Borrelli
Journal:  Injury       Date:  1997       Impact factor: 2.586

5.  Interlocking nails for displaced metaphyseal fractures of the distal tibia.

Authors:  Cheng-Yu Fan; Chao-Ching Chiang; Tien-Yow Chuang; Fang-Yao Chiu; Tain-Hsiung Chen
Journal:  Injury       Date:  2005-05       Impact factor: 2.586

6.  Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation.

Authors:  Gun-Il Im; Suk-Kee Tae
Journal:  J Trauma       Date:  2005-11

7.  Use of an articulated external fixator for fractures of the tibial plafond.

Authors:  J L Marsh; S Bonar; J V Nepola; T A Decoster; S R Hurwitz
Journal:  J Bone Joint Surg Am       Date:  1995-10       Impact factor: 5.284

8.  Percutaneous plating of distal tibial fractures.

Authors:  Amal Khoury; Meir Liebergall; Eli London; Rami Mosheiff
Journal:  Foot Ankle Int       Date:  2002-09       Impact factor: 2.827

9.  Percutaneous plating of distal tibial fractures.

Authors:  Nicola Maffulli; Andrew D Toms; Andrew McMurtie; Francesco Oliva
Journal:  Int Orthop       Date:  2004-02-14       Impact factor: 3.075

10.  Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?

Authors:  Karl Stoffel; Ulrich Dieter; Gwidon Stachowiak; André Gächter; Markus S Kuster
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

View more
  36 in total

1.  Augmentation of implant fixation in osteoporotic bone.

Authors:  Clifford B Jones
Journal:  Curr Osteoporos Rep       Date:  2012-12       Impact factor: 5.096

2.  Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients.

Authors:  Rafiq Bhat; Mubashir Maqbool Wani; Shakir Rashid; Nahida Akhter
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-20

3.  Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures.

Authors:  Vishwanath Yaligod; Girish H Rudrappa; Srinivas Nagendra; Umesh M Shivanna
Journal:  J Orthop       Date:  2013-12-27

4.  Management of fractures of the distal third tibia by minimally invasive plate osteosynthesis - A prospective series of 50 patients.

Authors:  Siddhartha Venkata Paluvadi; Hitesh Lal; Deepak Mittal; Kandarp Vidyarthi
Journal:  J Clin Orthop Trauma       Date:  2014-08-31

5.  Minimally Invasive Plate Osteosynthesis with Locking Plates for Distal Tibia Fractures.

Authors:  Ajeet Dhakar; Rajendra Annappa; Mahesh Gupta; Hemeshwar Harshwardhan; Prem Kotian; Pooja K Suresh
Journal:  J Clin Diagn Res       Date:  2016-03-01

6.  Hardware Removal Due to Infection after Open Reduction and Internal Fixation: Trends and Predictors.

Authors:  Mohammad R Rasouli; Jessica Viola; Mitchell G Maltenfort; Alisina Shahi; Javad Parvizi; James C Krieg
Journal:  Arch Bone Jt Surg       Date:  2015-07

7.  Management of distal third tibial fractures: comparison of combined internal and external fixation with minimally invasive percutaneous plate osteosynthesis.

Authors:  Liao-Jun Sun; Zhi-Peng Wu; Xiao-Shan Guo; Hua Chen
Journal:  Int Orthop       Date:  2014-08-03       Impact factor: 3.075

8.  Minimally invasive percutaneous plate fixation of tibia fractures: results in 80 patients.

Authors:  Alexandre A Sitnik; Alexander V Beletsky
Journal:  Clin Orthop Relat Res       Date:  2013-09       Impact factor: 4.176

9.  Management of high-energy foot and ankle injuries in the geriatric population.

Authors:  Dolfi Herscovici; Julia M Scaduto
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-03

10.  Soft tissue complications in distal tibial fractures managed with medial locking plates: A myth or reality?

Authors:  Deepak Jain; Harpal Singh Selhi; Mohammad Yamin; Pankaj Mahindra
Journal:  J Clin Orthop Trauma       Date:  2017-07-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.