Literature DB >> 16894823

Ultraviolet spectrophotometry as an index parameter for estimating the biochemical oxygen demand of domestic wastewater.

M Nataraja1, Y Qin, E A Seagren.   

Abstract

The relationship between ultraviolet absorbance at 280 nm (UV280) and the 5-day Biochemical Oxygen Demand (BOD5) test was evaluated using wastewater samples collected during March - December 1998 from the Fort Meade wastewater treatment plant (Maryland, U.S.A.). Three types of samples were collected: raw influent wastewater, primary effluent, and the effluent from the nitrification settling basin. A regression of BOD5 on UV280 was obtained using half of the data, with the other half of the data used to test application of the equation. The presence of NO3 and NO2, did not interfere with the BOD5/UV relationship. However, the relative fraction of organic compounds that absorb at UV280 and are biodegradable did appear to decrease across the treatment plant, thereby reducing the strength of the association between BOD5 and UV280 further along the treatment train. Interestingly, the exclusion of solids > 1 microm from the BOD5 test did not strengthen the association between BOD5 and UV280. These results suggest that simple UV absorbance measurements may be a useful analytical tool for wastewater treatment personnel, allowing them to quickly monitor for changes in the BOD5 during the treatment process and to quickly estimate the BOD5 when determining what dilutions to use in the standard BOD5 test. However, such relationships are likely to be wastewater and treatment plant specific and variable with time and treatment.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16894823     DOI: 10.1080/09593332708618691

Source DB:  PubMed          Journal:  Environ Technol        ISSN: 0959-3330            Impact factor:   3.247


  6 in total

1.  Applicability of Fluorescence and Absorbance Spectroscopy to Estimate Organic Pollution in Rivers.

Authors:  Heloise Garcia Knapik; Cristovão Vicente Scapulatempo Fernandes; Júlio Cesar Rodrigues de Azevedo; Monica Ferreira do Amaral Porto
Journal:  Environ Eng Sci       Date:  2014-12-01       Impact factor: 1.907

2.  Estimating the biodegradability of treated sewage samples using synchronous fluorescence spectra.

Authors:  Tien M Lai; Jae-Ki Shin; Jin Hur
Journal:  Sensors (Basel)       Date:  2011-07-25       Impact factor: 3.576

3.  Prediction of BOD, COD, and total nitrogen concentrations in a typical urban river using a fluorescence excitation-emission matrix with PARAFAC and UV absorption indices.

Authors:  Jin Hur; Jinwoo Cho
Journal:  Sensors (Basel)       Date:  2012-01-16       Impact factor: 3.576

4.  Estimation of biological oxygen demand and chemical oxygen demand for combined sewer systems using synchronous fluorescence spectra.

Authors:  Jin Hur; Bo-Mi Lee; Tae-Hwan Lee; Dae-Hee Park
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

Review 5.  Fibre optic sensors for selected wastewater characteristics.

Authors:  Su Sin Chong; A R Abdul Aziz; Sulaiman W Harun
Journal:  Sensors (Basel)       Date:  2013-07-05       Impact factor: 3.576

6.  Effect of colloid-size copper-based pesticides and wood-preservatives against microbial activities of Gram-positive Bacillus species using five-day biochemical oxygen demand test.

Authors:  Ayenachew Tegenaw; George A Sorial; Endalkachew Sahle-Demessie
Journal:  J Environ Sci (China)       Date:  2021-01-14       Impact factor: 6.796

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.