Literature DB >> 16894580

Three-dimensional MRI with an undersampled spherical shells trajectory.

Yunhong Shu1, Stephen J Riederer, Matt A Bernstein.   

Abstract

The shells trajectory is a 3D data acquisition method with improved efficiency compared to Cartesian sampling. It is a true center-out trajectory that does not repeatedly resample the center of k-space, and also offers advantages for motion correction. This work demonstrates that k-space undersampling can be combined with the shells trajectory to further accelerate the acquisition. The undersampling was implemented by removing selected interleaves from shells with larger radii. Because only the outer portion of k-space was undersampled, the artifacts introduced were of low energy and high spatial frequency. The undersampling rate was determined by a Kaiser window with a variable shape parameter beta. Various undersampling schemes with different beta values were examined. Phantom and volunteer studies demonstrate that when up to a twofold acceleration is achieved, only minor artifacts are introduced by undersampling the shells trajectory. For a fixed acquisition time, the improved efficiency can be used to increase spatial resolution. Copyright (c) 2006 Wiley-Liss, Inc.

Mesh:

Year:  2006        PMID: 16894580     DOI: 10.1002/mrm.20977

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Partial fourier shells trajectory for non-cartesian MRI.

Authors:  Shengzhen Tao; Yunhong Shu; Joshua D Trzasko; John Huston; Matt A Bernstein
Journal:  Phys Med Biol       Date:  2019-02-06       Impact factor: 3.609

2.  3D magnetization-prepared imaging using a stack-of-rings trajectory.

Authors:  Holden H Wu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

3.  Magnetization-prepared shells trajectory with automated gradient waveform design.

Authors:  Yunhong Shu; Shengzhen Tao; Joshua D Trzasko; John Huston; Paul T Weavers; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

4.  Three-dimensional magnetization-prepared imaging using a concentric cylinders trajectory.

Authors:  Kie Tae Kwon; Holden H Wu; Taehoon Shin; Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2013-07-01       Impact factor: 4.668

5.  Single shot three-dimensional pulse sequence for hyperpolarized 13 C MRI.

Authors:  Jiazheng Wang; Alan J Wright; De-En Hu; Richard Hesketh; Kevin M Brindle
Journal:  Magn Reson Med       Date:  2016-02-24       Impact factor: 4.668

Review 6.  15 Years MR-encephalography.

Authors:  Juergen Hennig; Vesa Kiviniemi; Bruno Riemenschneider; Antonia Barghoorn; Burak Akin; Fei Wang; Pierre LeVan
Journal:  MAGMA       Date:  2020-10-20       Impact factor: 2.310

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.