Literature DB >> 16894324

A technique for analysis of geometric mean renography.

John S Fleming1.   

Abstract

BACKGROUND AND OBJECTIVES: Renography is used routinely to assess relative right to left renal function. Quantification is usually carried out using posterior images. Errors in relative renal function may occur if the kidneys are at different depths. Geometric mean images from combined anterior and posterior views are much less affected by kidney depth and offer the opportunity of more accurate and precise quantification. Background subtraction is a key part of the analysis process and validated protocols for geometric mean imaging have not been devised. This study aims to derive a suitable background subtraction protocol for geometric mean imaging.
METHODS: Simultaneous anterior and posterior renography using Tc mercaptoacetyltriglycine (MAG3) was performed on 16 adults. Analysis was carried out using both geometric mean and posterior images. The geometric mean background subtraction protocol was modified to give the same results as a posterior method, which had previously been validated by correlation with measurements of glomerular filtration rate. Absolute and relative uptakes were then obtained from both geometric mean and posterior analyses. For each analysis values were obtained both with and without depth correction.
RESULTS: A revised background subtraction protocol for geometric mean renography was devised which operated successfully on all studies. Both absolute renal uptake and relative function values obtained from geometric mean analysis were not systematically different from those obtained using posterior analysis with depth correction. Values of the relative renal function from posterior analysis after depth correction were closer to the geometric mean values than estimates obtained before correction.
CONCLUSION: A technique for analysing geometric mean renography data has been developed which gives results consistent with a previously validated posterior-only method.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16894324     DOI: 10.1097/01.mnm.0000230070.16200.71

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  6 in total

1.  The SNMMI and EANM practice guideline for renal scintigraphy in adults.

Authors:  M Donald Blaufox; Diego De Palma; Andrew Taylor; Zsolt Szabo; Alain Prigent; Martin Samal; Yi Li; Andrea Santos; Giorgio Testanera; Mark Tulchinsky
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-08-30       Impact factor: 9.236

2.  Impact of geometric mean imaging in the accurate determination of partial function in MAG3 renal scanning in a patient with retroperitoneal mass.

Authors:  Mustafa Takesh; Christian M Zechmann; Sabine Haufe; Frederik L Giesel; Clemens Kratochwil
Journal:  J Radiol Case Rep       Date:  2011-06-01

3.  Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality.

Authors:  Ines Njeh; Kalil Chtourou; Ahmed BenHamida
Journal:  J Healthc Eng       Date:  2020-05-26       Impact factor: 2.682

4.  Optimizing scintigraphic evaluation of split renal function in living kidney donors using the geometric mean method: a preliminary retrospective study.

Authors:  Sarah Weinberger; Michael Baeder; Christian Scheurig-Muenkler; Ingo Guenter Steffen; Ahmed Magheli; Kurt Miller; Carsten Kempkensteffen
Journal:  J Nephrol       Date:  2015-08-19       Impact factor: 3.902

5.  Optimizing evaluation of split renal function in a living kidney donor using scintigraphy and calculation of the geometric mean: a case report.

Authors:  S Weinberger; M Bäder; C Scheurig-Münkler; S Hinz; J Neymeyer; K Miller; C Kempkensteffen
Journal:  Case Rep Nephrol Urol       Date:  2014-01-10

6.  Deconvolution of Tc-99m-Mercaptoacetyltriglycine Renograms with the Concomitant Use of a Sparse Legendre Polynomial Representation and the Moore-Penrose Pseudo-inverse.

Authors:  Michel Destine; François-Xavier Hanin; Isabelle Mathieu; Bernard Willemart; Alain Seret
Journal:  Mol Imaging Radionucl Ther       Date:  2022-02-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.