Literature DB >> 16889144

Clinical and radiological outcome following total hip arthroplasty with an uncemented trabecular metal monoblock acetabular cup.

Baskaran Komarasamy1, Ramanan Vadivelu, Andrew Bruce, Christopher Kershaw, John Davison.   

Abstract

Uncemented acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. The new tantalum/polyethylene composite (Hedrocel) acetabular component is designed to reduce the polyethylene wear and to increase the longevity of the acetabular cups. We report our short- term clinical outcome and patient satisfaction following use of an uncemented tantalum acetabular component in a single centre. During 1999 to 2002, 113 uncemented tantalum acetabular cups were implanted in 105 patients in our institution. The average age at operation was 56.8 years. All patients were assessed pre- and post-operatively with the Oxford 12 item hip questionnaire and standard radiographs of the pelvis. At a mean follow-up of 32 months (range: 18 to 48), 112 Hedrocel cups were assessed in 104 patients. Subjective patient's satisfaction was also assessed. At the time of evaluation, one patient had died due to an unrelated cause. Eight patients had bilateral acetabular cups implanted. The mean Oxford hip score improved from 45 preoperatively to 14 post-operatively. Subjectively 99% were very satisfied or satisfied. Only one patient expressed dissatisfaction about the outcome of this surgery. Radiologically, there were no signs of cup loosening or wear. This study shows that at short-term the new uncemented tantalum/polyethylene composite (Hedrocel) acetabular component can yield a satisfactory clinical and radiological outcome and has a high patient satisfaction. Although the short-term result from our centre is very encouraging, similar results from other centres and longer follow-up are required.

Entities:  

Mesh:

Year:  2006        PMID: 16889144

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  9 in total

1.  Multicentre use of a porous tantalum monoblock acetabular component.

Authors:  Th A Xenakis; G A Macheras; K S Stafilas; A T Kostakos; K Bargiotas; K N Malizos
Journal:  Int Orthop       Date:  2008-05-29       Impact factor: 3.075

2.  Smoking may be a harbinger of early failure with ultraporous metal acetabular reconstruction.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Ryan C Jefferson; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

Review 3.  Tantalum Versus Titanium Acetabular Cups in Primary Total Hip Arthroplasty: Current Concept and a Review of the Current Literature.

Authors:  Rohit Rambani; Mayur Nayak; Miss Sheweidin Aziz; Krishan Almeida
Journal:  Arch Bone Jt Surg       Date:  2022-05

Review 4.  Role of Hip Arthroscopy in the Treatment of Avascular Necrosis of the Hip: A Systematic Review.

Authors:  Omid Shahpari; Javad Mortazavi; Mohammad H Ebrahimzadeh; Farshid Bagheri; Alireza Mousavian
Journal:  Arch Bone Jt Surg       Date:  2022-06

5.  Survivorship of monoblock trabecular metal cups in primary THA : midterm results.

Authors:  Konstantinos N Malizos; Konstantinos Bargiotas; Loukia Papatheodorou; Michael Hantes; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

6.  Bone ingrowth in well-fixed retrieved porous tantalum implants.

Authors:  Josa A Hanzlik; Judd S Day
Journal:  J Arthroplasty       Date:  2013-03-18       Impact factor: 4.757

7.  A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients.

Authors:  Xiao Geng; Yang Li; Feng Li; Xinguang Wang; Ke Zhang; Zhongjun Liu; Hua Tian
Journal:  J Orthop Surg Res       Date:  2020-09-04       Impact factor: 2.359

8.  Analysis of bone ingrowth on a tantalum cup.

Authors:  F D'Angelo; L Murena; M Campagnolo; G Zatti; P Cherubino
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

9.  Preliminary analysis on the MD-4(®) plasma-sprayed titanium acetabular component.

Authors:  Elmano de Araújo Loures; Leandro Furtado Simoni; Isabel Cristina Gonçalves Leite; Daniel Naya Loures; Clarice Naya Loures
Journal:  Rev Bras Ortop       Date:  2015-03-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.