Literature DB >> 16882897

Computerized navigation for the internal fixation of femoral neck fractures.

Meir Liebergall1, Dror Ben-David, Yoram Weil, Amos Peyser, Rami Mosheiff.   

Abstract

BACKGROUND: Accurate placement of cannulated screws is essential to ensure secure fixation of femoral neck fractures. We compared computerized navigation and conventional fluoroscopy with regard to the accuracy of screw placement for the fixation of femoral neck fractures.
METHODS: We retrospectively compared two groups of twenty consecutive patients with a femoral neck fracture who underwent internal fixation with three cannulated screws. Computer-based navigation was used to guide screw placement in one group, and conventional fluoroscopy was used in the other group. Radiographic evaluation included the measurement of screw parallelism and spread, the calibrated distance from the lesser trochanter, and joint penetration. The follow-up period was two years. The rates of complications in both groups were evaluated.
RESULTS: The navigation-assisted group had better screw parallelism and greater spread of the screws. There was a tendency for fewer reoperations and significantly fewer overall complications in the patients in whom computerized navigation was used (p < 0.018).
CONCLUSIONS: Computerized navigation improves the accuracy of cannulated screw placement in the internal fixation of femoral neck fractures. It may provide better mechanical stability and improved fracture outcome.

Entities:  

Mesh:

Year:  2006        PMID: 16882897     DOI: 10.2106/JBJS.E.00137

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  13 in total

1.  Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study.

Authors:  Marcus Christian Müller; Peter Belei; Peter H Pennekamp; Koroush Kabir; Dieter C Wirtz; Christof Burger; Oliver Weber
Journal:  Int Orthop       Date:  2012-02-23       Impact factor: 3.075

2.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

3.  [Precision of guidewire placement--can it be improved by applying the new, isocentric aiming principle?].

Authors:  N Suhm; P Toggwiler; M Hänni; V Quarz; A Appelt
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

4.  [Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws. An experimental study].

Authors:  M C Müller; P Belei; M de la Fuente; M Strake; K Kabir; O Weber; C Burger; K Radermacher; D C Wirtz
Journal:  Unfallchirurg       Date:  2012-09       Impact factor: 1.000

5.  Error range in proximal femoral osteotomy using computer tomography-based navigation.

Authors:  Masaki Takao; Takashi Sakai; Hidetoshi Hamada; Nobuhiko Sugano
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-04-01       Impact factor: 2.924

6.  A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study.

Authors:  Varah Yuenyongviwat; Pakjai Tuntarattanapong; Boonsin Tangtrakulwanich
Journal:  BMC Musculoskelet Disord       Date:  2016-01-11       Impact factor: 2.362

7.  Technology of percutaneous cannulated screw implantation using screw view model of navigation in Garden type I of femoral neck fracture: A case report.

Authors:  Tong Yu; Bao-Ming Yuan; Xi-Wen Zhang; Dong-Sheng Wang; Yi-Kun Jiang; Rong-Peng Dong; Ming-Yang Kang; Xin Zhao; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

8.  TiRobot-Assisted Percutaneous Cannulated Screw Fixation in the Treatment of Femoral Neck Fractures: A Minimum 2-Year Follow-up of 50 Patients.

Authors:  Zong-Dong Zhu; Cheng-Wei Xiao; Bo Tan; Xiao-Ming Tang; Dan Wei; Jia-Bin Yuan; Jiang Hu; Liao Feng
Journal:  Orthop Surg       Date:  2021-01-15       Impact factor: 2.071

9.  2D-fluoroscopic based navigation for Gamma 3 nail insertion versus conventional procedure- a feasibility study.

Authors:  A Wilharm; I Marintschev; G O Hofmann; F Gras
Journal:  BMC Musculoskelet Disord       Date:  2013-02-28       Impact factor: 2.362

10.  Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study.

Authors:  Matthias Regling; Arno Blau; Robert A Probe; James W Maxey; Brian D Solberg
Journal:  BMC Musculoskelet Disord       Date:  2014-05-30       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.