Literature DB >> 16877596

Serum aluminium and cobalt levels after ceramic-on-ceramic and metal-on-metal total hip replacement.

A Grübl1, M Weissinger, W Brodner, A Gleiss, A Giurea, M Gruber, G Pöll, V Meisinger, F Gottsauner-Wolf, R Kotz.   

Abstract

In a randomised study, 28 patients with a mean age of 62.2 years (32 to 81) with osteoarthritis or avascular necrosis of the hip received either a ceramic-on-ceramic or a metal-on-metal total hip replacement. Apart from the liners the acetabular and femoral components were made of Ti-Al-Nb alloy. The serum aluminium and cobalt levels were measured before, and at one year after surgery. The 15 patients in the ceramic-on-ceramic group had a median pre-operative aluminium level of 1.3 microg/l (0.25 to 8.4) and a cobalt level below the detection limit. At one year the aluminium level was 1.1 microg/l (0.25 to 2.3) and the cobalt level was 0.4 microg/l (0.15 to 0.7). The 13 patients in the metal-on-metal group had a median pre-operative aluminium level of 1.9 microg/l (0.25 to 4.4) and a cobalt level below the detection limit. At one year the median aluminium level was 0.9 microg/l (0.25 to 3.9) whereas the cobalt level was 1.4 microg/l (0.5 to 10.5). This increase in the cobalt level at one year was significant (p < 0.001). Our findings indicate that ceramic-on-ceramic bearings do not cause elevated levels of serum aluminium in the first post-operative year.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16877596     DOI: 10.1302/0301-620X.88B8.17870

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  A painful soft tissue mass secondary to impingement of a metal on polyethylene bearing total hip arthroplasty.

Authors:  Griffiths-Jones William; Williams Daniel
Journal:  BMJ Case Rep       Date:  2014-05-20

2.  Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing.

Authors:  Alister J Hart; John A Skinner; Johann Henckel; Barry Sampson; Fabiana Gordon
Journal:  Clin Orthop Relat Res       Date:  2011-06-09       Impact factor: 4.176

3.  Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty.

Authors:  Nicholas B Frisch; Nolan M Wessell; Kevin Taliaferro; Marnix Van Holsbeeck; Craig D Silverton
Journal:  Skeletal Radiol       Date:  2017-02-15       Impact factor: 2.199

Review 4.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11

Review 5.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

Review 6.  Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

Authors:  Albrecht Hartmann; Franziska Hannemann; Jörg Lützner; Andreas Seidler; Hans Drexler; Klaus-Peter Günther; Jochen Schmitt
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

Review 7.  Increased Mortality in Metal-on-Metal versus Non-Metal-on-Metal Primary Total Hip Arthroplasty at 10 Years and Longer Follow-Up: A Systematic Review and Meta-Analysis.

Authors:  B G Pijls; J M T A Meessen; J W Schoones; M Fiocco; H J L van der Heide; A Sedrakyan; R G H H Nelissen
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.