Literature DB >> 16876263

Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from London: comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx HIV RNA Quantitative assays.

Priscilla Swanson1, Vera Holzmayer, Shihai Huang, Phillip Hay, Ade Adebiyi, Philip Rice, Klara Abravaya, Sven Thamm, Sushil G Devare, John Hackett.   

Abstract

Automated RNA extraction and quantitation of HIV-1 by real-time PCR offer potential advantages of efficient sample processing, improved sensitivity, expanded dynamic range and reduced contamination risk. In this study, plasma was collected from 100 HIV-1 infected patients visiting The Courtyard Clinic of St. George's Hospital in London, United Kingdom (UK). Viral loads measured using the automated Abbott RealTime HIV-1 assay (m2000sp sample preparation and m2000rt amplification and detection instruments) were compared to results obtained with Versant HIV-1 RNA 3.0 (bDNA), AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) and LCx HIV RNA Quantitative (LCx HIV) assays. Based on gag p24, pol integrase, and env gp41 sequences, the panel included 26 subtype A, 20 B, 27 C, 10 D, 1 CRF01_AE, 3 CRF02_AG and 13 recombinant viruses. RealTime HIV-1, bDNA, Monitor v1.5 and LCx HIV quantitated 82, 74, 82, and 83% of samples, respectively, with 82, 71, 69 and 80 of the 100 samples measured within the dynamic ranges. Viral loads were highly correlated with 99% of values within 1 log(10) copies/ml between tests. The automated m2000 system and RealTime HIV-1 assay can increase laboratory throughput, enhance overall efficiency and reduce operator-associated errors while providing reliable quantitation of genetically diverse strains of HIV-1.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16876263     DOI: 10.1016/j.jviromet.2006.06.010

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  19 in total

1.  Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

Authors:  Sihong Xu; Aijing Song; Jianhui Nie; Xiuhua Li; Youchun Wang
Journal:  Mol Diagn Ther       Date:  2010-10-01       Impact factor: 4.074

2.  Immiscible phase nucleic acid purification eliminates PCR inhibitors with a single pass of paramagnetic particles through a hydrophobic liquid.

Authors:  Kunal Sur; Sally M McFall; Emilie T Yeh; Sujit R Jangam; Mark A Hayden; Stephen D Stroupe; David M Kelso
Journal:  J Mol Diagn       Date:  2010-06-25       Impact factor: 5.568

3.  Evaluation of the Abbott investigational use only realtime HIV-1 assay and comparison to the Roche Amplicor HIV-1 monitor test, version 1.5.

Authors:  Michael T Pyne; Eric Q Konnick; Amit Phansalkar; David R Hillyard
Journal:  J Mol Diagn       Date:  2009-05-21       Impact factor: 5.568

4.  Evaluation of the Cavidi ExaVir Load assay (version 3) for plasma human immunodeficiency virus type 1 load monitoring.

Authors:  Vicki L Greengrass; Megan M Plate; Pauline M Steele; Justin T Denholm; Catherine L Cherry; Lisa M Morris; Anna Hearps; Suzanne M Crowe
Journal:  J Clin Microbiol       Date:  2009-07-15       Impact factor: 5.948

5.  Performance of the Abbott RealTime HIV-1 viral load assay is not impacted by integrase inhibitor resistance-associated mutations.

Authors:  Thomas P Young; Gavin Cloherty; Signe Fransen; Laura Napolitano; Priscilla Swanson; Christine Herman; Neil T Parkin; John Hackett
Journal:  J Clin Microbiol       Date:  2011-02-02       Impact factor: 5.948

6.  Does Size Matter? Comparison of Extraction Yields for Different-Sized DNA Fragments by Seven Different Routine and Four New Circulating Cell-Free Extraction Methods.

Authors:  Linda Cook; Kimberly Starr; Jerry Boonyaratanakornkit; Randall Hayden; Soya S Sam; Angela M Caliendo
Journal:  J Clin Microbiol       Date:  2018-11-27       Impact factor: 5.948

7.  Sequence conservation of the region targeted by the Abbott RealTime HBV viral load assay in clinical specimens.

Authors:  Gavin A Cloherty; James Rhoads; Thomas P Young; Neil T Parkin; Vera Holzmayer; Lilly Yuen; Carolyn Mullen
Journal:  J Clin Microbiol       Date:  2013-01-23       Impact factor: 5.948

8.  Single real-time reverse transcription-PCR assay for detection and quantification of genetically diverse HIV-1, SIVcpz, and SIVgor strains.

Authors:  Lucie Etienne; Sabrina Eymard-Duvernay; Avelin Aghokeng; Christelle Butel; Marjorie Monleau; Martine Peeters
Journal:  J Clin Microbiol       Date:  2012-12-19       Impact factor: 5.948

9.  Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

Authors:  Lesley E Scott; Lara D Noble; Jackie Moloi; Linda Erasmus; Willem D F Venter; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

10.  Viral load levels measured at set-point have risen over the last decade of the HIV epidemic in the Netherlands.

Authors:  Luuk Gras; Suzanne Jurriaans; Margreet Bakker; Ard van Sighem; Daniela Bezemer; Christophe Fraser; Joep Lange; Jan M Prins; Ben Berkhout; Frank de Wolf
Journal:  PLoS One       Date:  2009-10-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.