Literature DB >> 19460935

Evaluation of the Abbott investigational use only realtime HIV-1 assay and comparison to the Roche Amplicor HIV-1 monitor test, version 1.5.

Michael T Pyne1, Eric Q Konnick, Amit Phansalkar, David R Hillyard.   

Abstract

Abbott Molecular's m2000 system and RealTime HIV-1 assay (RealTime) were evaluated for sensitivity, reproducibility, linearity, ability to detect diverse HIV-1 subtypes/groups, and correlation to the Roche AMPLICOR HIV-1 MONITOR Test, Version 1.5 (Amplicor). The limit of detection was determined using the second International World Health Organization Standard and Viral Quality Assurance standard material. Serial dilutions of four patient samples were used to determine inter- and intra-assay reproducibility and linearity. Samples representing HIV-1 groups M, N, and O were evaluated in the RealTime, Amplicor, and Siemens Versant HIV-1 branched chain DNA 3.0 (Versant) assays. Archived Amplicor-tested samples were tested with the 1 ml, 0.5 ml, and 0.6 ml versions of the RealTime assay. Probit analysis predicts a limit of detection of 21.94 IU/ml using the World Health Organization Standard and 26.54 copies/ml using Viral Quality Assurance material with the 1 ml assay. Linearity and reproducibility were very good between approximately 1.60 to 6.0 log(10) copies/ml. All three assays produced similar measurements for all Group M subtypes tested; the RealTime assay was the only assay that detected all three Group O samples tested. Correlation with the Amplicor assay was good, although the RealTime assay measured between 0.342 and 0.716 log(10) copies/ml lower on average, depending on the input volume. The automated RealTime assay exhibits excellent sensitivity, dynamic range, reproducibility, and group/subtype detection, albeit with consistently lower values than Amplicor.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19460935      PMCID: PMC2710712          DOI: 10.2353/jmoldx.2009.080166

Source DB:  PubMed          Journal:  J Mol Diagn        ISSN: 1525-1578            Impact factor:   5.568


  21 in total

1.  General deming regression for estimating systematic bias and its confidence interval in method-comparison studies.

Authors:  R F Martin
Journal:  Clin Chem       Date:  2000-01       Impact factor: 8.327

2.  Comparison of LCx with other current viral load assays for detecting and quantifying human immunodeficiency virus type 1 RNA in patients infected with the circulating recombinant form A/G (CRF02).

Authors:  Alessandra Amendola; Licia Bordi; Claudio Angeletti; Enrico Girardi; Giuseppe Ippolito; Maria R Capobianchi
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

3.  Failure to detect a non-B HIV-1 subtype by the HIV-1 Amplicor Monitor test, version 1.5: a case of unexpected vertical transmission.

Authors:  Sibyl Geelen; Joep Lange; Jan Borleffs; Tom Wolfs; Annemarie Weersink; Rob Schuurman
Journal:  AIDS       Date:  2003-03-28       Impact factor: 4.177

4.  Genetic characterization of diverse HIV-1 strains in an immigrant population living in New York City.

Authors:  Hsi-Hsun Lin; Brian K Gaschen; Mary Collie; Mona El-Fishaway; Zhiwei Chen; Bette T Korber; Sally T Beatrice; Linqi Zhang
Journal:  J Acquir Immune Defic Syndr       Date:  2006-04-01       Impact factor: 3.731

5.  Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from London: comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx HIV RNA Quantitative assays.

Authors:  Priscilla Swanson; Vera Holzmayer; Shihai Huang; Phillip Hay; Ade Adebiyi; Philip Rice; Klara Abravaya; Sven Thamm; Sushil G Devare; John Hackett
Journal:  J Virol Methods       Date:  2006-07-28       Impact factor: 2.014

6.  Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from Brazil.

Authors:  Priscilla Swanson; Shihai Huang; Vera Holzmayer; Pierre Bodelle; Julie Yamaguchi; Catherine Brennan; Roberto Badaro; Carlos Brites; Klara Abravaya; Sushil G Devare; John Hackett
Journal:  J Virol Methods       Date:  2006-02-28       Impact factor: 2.014

7.  Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma.

Authors:  Vincent Foulongne; Brigitte Montes; Marie-Noelle Didelot-Rousseau; Michel Segondy
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

8.  Real-time PCR assays for hepatitis C virus (HCV) RNA quantitation are adequate for clinical management of patients with chronic HCV infection.

Authors:  Philippe Halfon; Marc Bourlière; Guillaume Pénaranda; Hacène Khiri; Denis Ouzan
Journal:  J Clin Microbiol       Date:  2006-07       Impact factor: 5.948

9.  Estimated global distribution and regional spread of HIV-1 genetic subtypes in the year 2000.

Authors:  Saladin Osmanov; Claire Pattou; Neff Walker; Bernhard Schwardländer; Jose Esparza
Journal:  J Acquir Immune Defic Syndr       Date:  2002-02-01       Impact factor: 3.731

Review 10.  HIV-1 viral load assays for resource-limited settings.

Authors:  Susan A Fiscus; Ben Cheng; Suzanne M Crowe; Lisa Demeter; Cheryl Jennings; Veronica Miller; Richard Respess; Wendy Stevens
Journal:  PLoS Med       Date:  2006-10       Impact factor: 11.069

View more
  4 in total

1.  Transcriptional profiling of TLR-4/7/8-stimulated guinea pig splenocytes and whole blood by bDNA assay.

Authors:  Lance K Ching; Farah Mompoint; Jeffrey A Guderian; Alex Picone; Ian M Orme; Rhea N Coler; Steven G Reed; Susan L Baldwin
Journal:  J Immunol Methods       Date:  2011-08-03       Impact factor: 2.303

2.  Long-term control of viral replication in a Group O, human immunodeficiency virus type 1-infected individual.

Authors:  Robert W Buckheit; Stephen B Sexauer; Ahmad R Sedaghat; Claus O Wilke; Oliver Laeyendecker; Christie R Basseth; Joel N Blankson
Journal:  AIDS Res Hum Retroviruses       Date:  2014-06       Impact factor: 2.205

3.  Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test and identification of rare polymorphisms potentially affecting assay performance.

Authors:  Michael T Pyne; Katherine L Brown; David R Hillyard
Journal:  J Clin Microbiol       Date:  2010-06-23       Impact factor: 5.948

Review 4.  Systematic review of the performance of HIV viral load technologies on plasma samples.

Authors:  Kimberly A Sollis; Pieter W Smit; Susan Fiscus; Nathan Ford; Marco Vitoria; Shaffiq Essajee; David Barnett; Ben Cheng; Suzanne M Crowe; Thomas Denny; Alan Landay; Wendy Stevens; Vincent Habiyambere; Jos Perrins; Rosanna W Peeling
Journal:  PLoS One       Date:  2014-02-18       Impact factor: 3.240

  4 in total