Literature DB >> 16866564

Development of a combined microPET-MR system.

A J Lucas1, R C Hawkes, R E Ansorge, G B Williams, R E Nutt, J C Clark, T D Fryer, T A Carpenter.   

Abstract

As evidenced by the success of PET-CT, there are many benefits from combining imaging modalities into a single scanner. The combination of PET and MR offers potential advantages over PET-CT, including improved soft tissue contrast, access to the multiplicity of contrast mechanisms available to MR, simultaneous imaging and fast MR sequences for motion correction. In addition, PET-MR is more suitable than PET-CT for cancer screening due to the elimination of the radiation dose from CT. A key issue associated with combining PET and MR is the fact that the performance of the photomultiplier tubes (PMTs) used in conventional PET detectors is degraded in the magnetic field required for MR. Two approaches have been adopted to circumvent that issue: retention of conventional, magnetic field-sensitive PMT-based PET detectors by modification of other features of the MR or PET system, or the use of new, magnetic field-insensitive devices in the PET detectors including avalanche photo-diodes (APDs) and silicon photomultipliers (SiPMs). Taking the former approach, we are assembling a modified microPET Focus 120 within a gap in a novel, 1T superconducting magnet. The PMTs are located in a low magnetic field (approximately 30mT) through a combination of magnet design and the use of fiber optic 'bundles'. Two main features of the modified PET system have been tested, namely the effect of using long fiber optic bundles in the PET detector, and the impact of magnetic field upon the performance of the position sensitive PMTs. The design of a modified microPET-MR system for small animal imaging is completed, and assembly and testing is underway.

Entities:  

Mesh:

Year:  2006        PMID: 16866564     DOI: 10.1177/153303460600500405

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  32 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.

Authors:  Hans F Wehrl; Martin S Judenhofer; Axel Thielscher; Petros Martirosian; Fritz Schick; Bernd J Pichler
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

3.  PET Performance Evaluation of an MR-Compatible PET Insert.

Authors:  Yibao Wu; Ciprian Catana; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

4.  Reliability of using a fixed matrix in coregistration of combined PET-MRI in a split magnet design.

Authors:  Sj Sawiak; Rc Hawkes; Re Ansorge; Ta Carpenter
Journal:  Nucl Instrum Methods Phys Res A       Date:  2013-02-21       Impact factor: 1.455

5.  MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

Authors:  Ciprian Catana; Thomas Benner; Andre van der Kouwe; Larry Byars; Michael Hamm; Daniel B Chonde; Christian J Michel; Georges El Fakhri; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2011-01       Impact factor: 10.057

6.  Simultaneous in vivo positron emission tomography and magnetic resonance imaging.

Authors:  Ciprian Catana; Daniel Procissi; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Russell E Jacobs; Simon R Cherry
Journal:  Proc Natl Acad Sci U S A       Date:  2008-03-04       Impact factor: 11.205

Review 7.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

Review 8.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 9.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

10.  Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Authors:  Bo J Peng; Jeffrey H Walton; Simon R Cherry; Jacob Willig-Onwuachi
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.