Literature DB >> 16863968

Spherical aberration and contrast sensitivity after cataract surgery with the Tecnis Z9000 intraocular lens.

Gonzalo Muñoz1, César Albarrán-Diego, Robert Montés-Micó, Antonio Rodríguez-Galietero, Jorge L Alió.   

Abstract

PURPOSE: To determine whether implantation of an intraocular lens (IOL) with a modified prolate anterior surface (Tecnis Z9000, AMO) results in reduced spherical aberration and improved contrast sensitivity after cataract surgery.
SETTING: Hospital NISA Virgen del Consuelo, Valencia, Spain.
METHODS: In an intraindividual randomized prospective study of 30 patients with bilateral cataract, the Tecnis Z9000 IOL was compared with 2 IOLs with spherical surfaces, the AR40e (AMO) and the Stabibag (Ioltech). Ocular aberrations for a 4.0 mm pupil and 6.0 mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured by visual acuity and contrast sensitivity under mesopic and photopic conditions.
RESULTS: Eyes with the Tecnis Z9000 IOL had significantly less spherical aberration and a greater Strehl ratio after surgery. Significant reduction in coma aberration was also found in some cases. Refraction, visual acuity, and contrast sensitivity were not significantly different between the 3 IOL groups.
CONCLUSION: A significant reduction in spherical aberration after Tecnis Z9000 IOL implantation was achieved, but visual acuity and contrast sensitivity were not affected by the aspheric silicone IOL compared to spherical acrylic IOLs.

Entities:  

Mesh:

Year:  2006        PMID: 16863968     DOI: 10.1016/j.jcrs.2006.02.055

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  22 in total

1.  Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.

Authors:  Xian-Hui Gong; Qin-Xiang Zheng; Na Wang; Ding Chen; Juan Zhao; Jin Li; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

Review 2.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part II: examples].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-11       Impact factor: 1.059

Review 3.  [Apodized diffractive optic. New concept in multifocal lens technology].

Authors:  T Kohnen; V Derhartunian
Journal:  Ophthalmologe       Date:  2007-10       Impact factor: 1.059

4.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

5.  Wavefront analysis of acrylic spherical and aspherical intraocular lenses.

Authors:  Satoru Takeo; Yoichiro Watanabe; Misa Suzuki; Kazuaki Kadonosono
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

6.  Corneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery.

Authors:  Tarfah M Al-Sayyari; Samah M Fawzy; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2014-06-25

7.  Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens.

Authors:  Yuxin Zhao; Zhaoxia Wang; Xia Tian; Xuehong Wang; Xining Gao
Journal:  Int Ophthalmol       Date:  2017-05-30       Impact factor: 2.031

8.  Average gradient of Zernike polynomials over polygons.

Authors:  Vyas Akondi; Alfredo Dubra
Journal:  Opt Express       Date:  2020-06-22       Impact factor: 3.894

9.  Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.

Authors:  Myoung Joon Kim; Len Zheleznyak; Scott Macrae; Hungwon Tchah; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

10.  Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO.

Authors:  Ahmad-Reza Baghi; Mohammad-Reza Jafarinasab; Hossein Ziaei; Zahra Rahmani
Journal:  J Ophthalmic Vis Res       Date:  2008-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.