Literature DB >> 16828288

The Pedar in-shoe system: repeatability and normal pressure values.

A B Putti1, G P Arnold, L Cochrane, R J Abboud.   

Abstract

The Pedar system is one of the most commonly used systems for in-shoe pressure measurement. Good repeatability is necessary to ensure the consistency of measurements on which clinical judgements are based. In addition, there is a need to establish a range of normal in-shoe pressure values, which will help to identify abnormalities. The aim of this study was to assess the repeatability of the Pedar system and determine the pressure values in normal subjects. Fifty-three subjects, 17 females (32%) and 36 males (68%), were recruited and measurements were performed twice with an average gap of 12 days (range 1-32 days) using only one brand of standardised running shoes (Donnay International). Peak pressure (PP), contact area (CA), contact time (CT), pressure-time integral (PTI), force-time integral (FTI) and instant of peak pressure (IPP) were calculated. The coefficient of repeatability (CR), expressed as a percentage of the mean, was no greater than 15.3% for all 122 parameters considered. The highest PP areas were under the great toe, with mean (S.D.) equal to 280.4 (83.0) kPa and heel 264.3 (44.1) kPa, followed by the first 248 (70.1) kPa, second 246.5 (48.3) kPa, and third 224.7 (50.4) kPa metatarsal heads. The CA was highest under the heel at 41.54 cm(2). The CT of the metatarsals was 77% to 87% of the total CT while that of the hallux was 75%. The PTI and FTI were highest under the heel. We concluded that the Pedar system was repeatable. The normal pressure values identified can therefore be used to provide a reference range in clinical practice using this specific type of footwear.

Mesh:

Year:  2006        PMID: 16828288     DOI: 10.1016/j.gaitpost.2006.05.010

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  44 in total

1.  Computational techniques for using insole pressure sensors to analyse three-dimensional joint kinetics.

Authors:  Elizabeth S Chumanov; C David Remy; Darryl G Thelen
Journal:  Comput Methods Biomech Biomed Engin       Date:  2010-10       Impact factor: 1.763

2.  Investigation of foot plantar pressure: experimental and numerical analysis.

Authors:  A N Natali; A Forestiero; E L Carniel; P G Pavan; C Dal Zovo
Journal:  Med Biol Eng Comput       Date:  2010-11-10       Impact factor: 2.602

3.  Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements.

Authors:  Laetitia Fradet; Johannes Siegel; Marieke Dahl; Merkur Alimusaj; Sebastian I Wolf
Journal:  Med Biol Eng Comput       Date:  2008-08-26       Impact factor: 2.602

4.  [Forefoot relief with shoe inserts : Effects of different construction strategies].

Authors:  H Baur; N Merz; A Muster; G Flückiger; A Hirschmüller
Journal:  Z Rheumatol       Date:  2018-04       Impact factor: 1.372

5.  Decreased ratios of lateral to medial patellofemoral forces and pressures after lateral retinacular release and gender knees in total knee arthroplasty.

Authors:  Joseph J King; Rajit Chakravarty; Douglas L Cerynik; Aaron Black; Norman A Johanson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-09-28       Impact factor: 4.342

6.  Diabetic foot ulcer incidence in relation to plantar pressure magnitude and measurement location.

Authors:  William R Ledoux; Jane B Shofer; Matthew S Cowley; Jessie H Ahroni; Victoria Cohen; Edward J Boyko
Journal:  J Diabetes Complications       Date:  2013-09-04       Impact factor: 2.852

7.  Are old running shoes detrimental to your feet? A pedobarographic study.

Authors:  Ulfin Rethnam; Nilesh Makwana
Journal:  BMC Res Notes       Date:  2011-08-24

8.  [Cross stability in conventional shoes by the use of spring steel insoles: a pedobarographic effect study with observational application].

Authors:  N L Becker; T Obens; J Weisser; S Flick
Journal:  Orthopade       Date:  2014-09       Impact factor: 1.087

9.  Towards Biomimetic Virtual Constraint Control of a Powered Prosthetic Leg.

Authors:  Robert D Gregg; Jonathon W Sensinger
Journal:  IEEE Trans Control Syst Technol       Date:  2014-01       Impact factor: 5.485

10.  Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations.

Authors:  Andrea Tura; Michele Raggi; Laura Rocchi; Andrea G Cutti; Lorenzo Chiari
Journal:  J Neuroeng Rehabil       Date:  2010-01-19       Impact factor: 4.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.