Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT.

Wojciech Zbijewski1, Freek J Beekman.   

Abstract

Cupping and streak artifacts caused by the detection of scattered photons may severely degrade the quantitative accuracy of cone-beam X-ray computed tomography (CT) images. In order to overcome this problem, we propose and validate the following iterative scatter artifact reduction scheme. First, an initial image is reconstructed from the scatter-contaminated projections. Next, the scatter component of the projections is estimated from the initial reconstruction by a Monte Carlo (MC) simulation. The estimate obtained is then utilized during the reconstruction of a scatter-corrected image. The last two steps are repeated until an adequate correction is obtained. The estimation of the noise-free scatter projections in this scheme is accelerated in the following way: first, a rapid (i.e., based on a low number of simulated photon tracks) MC simulation is executed. The noisy result of this simulation is de-noised by a three-dimensional fitting of Gaussian basis functions. We demonstrate that, compared to plain MC, this method shortens the required simulation time by three to four orders of magnitude. Using simulated projections of a small animal phantom, we show that one cycle of the scatter correction scheme is sufficient to produce reconstructed images that barely differ from the reconstructions of scatter-free projections. The reconstructions of data acquired with a charge-coupled device based micro-CT scanner demonstrate a nearly complete removal of the scatter-induced cupping artifact. Quantitative errors in a water phantom are reduced from around 12% for reconstructions without the scatter correction to 1% after the proposed scatter correction has been applied. In conclusion, a general, accurate, and efficient scatter correction algorithm is developed that requires no mechanical modifications of the scanning equipment and results in only a moderate increase in the total reconstruction time.

Entities:  

Mesh:

Year:  2006        PMID: 16827483     DOI: 10.1109/tmi.2006.872328

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

Review 1.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

2.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

3.  Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT).

Authors:  Mingshan Sun; Tamás Nagy; Gary Virshup; Larry Partain; Markus Oelhafen; Josh Star-Lack
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

5.  Design of a digital beam attenuation system for computed tomography: part I. System design and simulation framework.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

7.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

8.  Library based x-ray scatter correction for dedicated cone beam breast CT.

Authors:  Linxi Shi; Srinivasan Vedantham; Andrew Karellas; Lei Zhu
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

9.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

10.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071