Literature DB >> 16826879

Dental alloys and magnetic resonance imaging.

Hana Hubálková1, Paola La Serna, Igor Linetskiy, Tat'jana Dostálová.   

Abstract

The aim of this review article is to describe the behaviour of dental alloys during the magnetic resonance imaging procedure. Mechanical and physical effects of a high frequency magnetic field are discussed. They may cause a movement or heating of metal objects present in the body, which can lead to a potential health risk for patients undergoing this examination. Metal objects with positive magnetic properties can influence magnetic resonance scans and the results of this procedure. Such negative effects are documented in experiments, theoretical studies and articles evaluating clinical trials. The safety of magnetic resonance and the compatibility of dental alloys must always be considered prior to the magnetic resonance imaging procedure.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16826879     DOI: 10.1111/j.1875-595x.2006.tb00085.x

Source DB:  PubMed          Journal:  Int Dent J        ISSN: 0020-6539            Impact factor:   2.512


  9 in total

1.  Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study.

Authors:  Yacine Noureddine; Andreas K Bitz; Mark E Ladd; Markus Thürling; Susanne C Ladd; Gregor Schaefers; Oliver Kraff
Journal:  MAGMA       Date:  2015-09-26       Impact factor: 2.310

2.  The effect of 3 T MRI on microleakage of amalgam restorations.

Authors:  S Yilmaz; M Misirlioglu
Journal:  Dentomaxillofac Radiol       Date:  2013-05-14       Impact factor: 2.419

3.  Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI.

Authors:  S Görgülü; S Ayyildiz; K Kamburoglu; S Gökçe; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2013-11-20       Impact factor: 2.419

4.  Magnetic resonance imaging artefacts caused by orthodontic appliances and/or implant-supported prosthesis: a systematic review.

Authors:  Katrine Mølgaard Johannsen; João Marcus de Carvalho E Silva Fuglsig; Brian Hansen; Ann Wenzel; Rubens Spin-Neto
Journal:  Oral Radiol       Date:  2022-09-30       Impact factor: 1.882

5.  Tongue fat and its relationship to obstructive sleep apnea.

Authors:  Andrew M Kim; Brendan T Keenan; Nicholas Jackson; Eugenia L Chan; Bethany Staley; Harish Poptani; Drew A Torigian; Allan I Pack; Richard J Schwab
Journal:  Sleep       Date:  2014-10-01       Impact factor: 5.849

6.  Artifacts in magnetic resonance imaging and computed tomography caused by dental materials.

Authors:  Thomas Klinke; Amro Daboul; Juliane Maron; Tomasz Gredes; Ralf Puls; Ahmad Jaghsi; Reiner Biffar
Journal:  PLoS One       Date:  2012-02-22       Impact factor: 3.240

7.  Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI.

Authors:  Jeanne M Gunzinger; Gaspar Delso; Andreas Boss; Miguel Porto; Helen Davison; Gustav K von Schulthess; Martin Huellner; Paul Stolzmann; Patrick Veit-Haibach; Irene A Burger
Journal:  EJNMMI Phys       Date:  2014-12-20

Review 8.  Unwanted effects due to interactions between dental materials and magnetic resonance imaging: a review of the literature.

Authors:  Sherin Jose Chockattu; Deepak Byathnal Suryakant; Sophia Thakur
Journal:  Restor Dent Endod       Date:  2018-08-30

9.  The interaction and interference of preformed metal crowns on magnetic resonance imaging: a scoping review with a systematic methodology.

Authors:  O Sumner; R Goldsmith; N Heath; G D Taylor
Journal:  Eur Arch Paediatr Dent       Date:  2021-06-11
  9 in total