Literature DB >> 16826608

Direct parallel image reconstructions for spiral trajectories using GRAPPA.

Robin M Heidemann1, Mark A Griswold, Nicole Seiberlich, Gunnar Krüger, Stephan A R Kannengiesser, Berthold Kiefer, Graham Wiggins, Lawrence L Wald, Peter M Jakob.   

Abstract

The use of spiral trajectories is an efficient way to cover a desired k-space partition in magnetic resonance imaging (MRI). Compared to conventional Cartesian k-space sampling, it allows faster acquisitions and results in a slight reduction of the high gradient demand in fast dynamic scans, such as in functional MRI (fMRI). However, spiral images are more susceptible to off-resonance effects that cause blurring artifacts and distortions of the point-spread function (PSF), and thereby degrade the image quality. Since off-resonance effects scale with the readout duration, the respective artifacts can be reduced by shortening the readout trajectory. Multishot experiments represent one approach to reduce these artifacts in spiral imaging, but result in longer scan times and potentially increased flow and motion artifacts. Parallel imaging methods are another promising approach to improve image quality through an increase in the acquisition speed. However, non-Cartesian parallel image reconstructions are known to be computationally time-consuming, which is prohibitive for clinical applications. In this study a new and fast approach for parallel image reconstructions for spiral imaging based on the generalized autocalibrating partially parallel acquisitions (GRAPPA) methodology is presented. With this approach the computational burden is reduced such that it becomes comparable to that needed in accelerated Cartesian procedures. The respective spiral images with two- to eightfold acceleration clearly benefit from the advantages of parallel imaging, such as enabling parallel MRI single-shot spiral imaging with the off-resonance behavior of multishot acquisitions. Copyright 2006 Wiley-Liss, Inc.

Mesh:

Year:  2006        PMID: 16826608     DOI: 10.1002/mrm.20951

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  36 in total

1.  Bilateral contrast-enhanced MR angiography of the hand: diagnostic image quality of accelerated MRI using echo sharing with interleaved stochastic trajectories (TWIST).

Authors:  Jan Thorsten Winterer; P Blanke; A Schaefer; G Pache; M Langer; M Markl
Journal:  Eur Radiol       Date:  2010-11-18       Impact factor: 5.315

2.  Parallel imaging reconstruction for arbitrary trajectories using k-space sparse matrices (kSPA).

Authors:  Chunlei Liu; Roland Bammer; Michael E Moseley
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

Review 3.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

4.  Improved self-calibrated spiral parallel imaging using JSENSE.

Authors:  Jinhua Sheng; Erik Wiener; Bo Liu; Fernando Boada; Leslie Ying
Journal:  Med Eng Phys       Date:  2008-11-21       Impact factor: 2.242

5.  Fast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction.

Authors:  Dirk Mayer; Dong-Hyun Kim; Daniel M Spielman; Roland Bammer
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

6.  Spiral tissue phase velocity mapping in a breath-hold with non-cartesian SENSE.

Authors:  Robin Simpson; Jennifer Keegan; Peter Gatehouse; Michael Hansen; David Firmin
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

Review 7.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

8.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

9.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

Review 10.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.