Comparison of femoral head penetration using RSA and the Martell method.

Charles R Bragdon1, John M Martell, Meridith E Greene, Daniel M Estok, Jonas Thanner, Johan Kärrholm, William H Harris, Henrik Malchau.   

Abstract

UNLABELLED: Radiostereometry has high precision and accuracy measuring polyethylene wear in total hip arthroplasty but requires a specialized setup. The Martell method is simpler and can be used on larger populations. The hypothesis that the radiostereometry analysis and the Martell analysis would yield comparable wear data from the same group of patients having total hip arthroplasty was tested. A group of twenty-five total hip arthroplasty patients who had both radiostereometry and standard anterior-posterior pelvic and cross-table lateral radiographs of sufficient quality for analysis were identified. The films were taken at postoperative periods of 6 weeks, 1 year, 2 years, and 5 years. Femoral head penetration was measured by both methods at each time point. The median penetration rates measured by each method decreased over time. Penetration results were affected by method of analysis, time, and dimension, with greater penetration for Martell compared with radiostereometry at each time point, greater penetration with increasing time for each method, and larger three-dimensional magnitude compared with two-dimensional analysis. LEVEL OF EVIDENCE: Case series Level IV. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2006        PMID: 16826096     DOI: 10.1097/01.blo.0000224018.88410.83

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  Does fluoroscopy improve acetabular component placement in total hip arthroplasty?

Authors:  Brandon S Beamer; Jordan H Morgan; Christopher Barr; Michael J Weaver; Mark S Vrahas
Journal:  Clin Orthop Relat Res       Date:  2014-09-20       Impact factor: 4.176

Review 2.  What are the current clinical issues in wear and tribocorrosion?

Authors:  Daniel J Berry; Matthew P Abdel; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

3.  Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty.

Authors:  Caroline Scemama; Claudio Dora; Jean Langlois; Moussa Hamadouche
Journal:  Int Orthop       Date:  2014-12-04       Impact factor: 3.075

4.  The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital.

Authors:  Mark C Callanan; Bryan Jarrett; Charles R Bragdon; David Zurakowski; Harry E Rubash; Andrew A Freiberg; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

5.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

6.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

7.  Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study.

Authors:  Stuart A Callary; John R Field; David G Campbell
Journal:  Clin Orthop Relat Res       Date:  2013-07-27       Impact factor: 4.176

8.  The Ringloc liner compared with the Hexloc liner in total hip arthroplasty.

Authors:  Sköldenberg Olof; Salemyr Mats; Muren Olle; Johansson Ake; Ahl Torbjörn; Bodén Henrik
Journal:  Orthop Rev (Pavia)       Date:  2009-10-10

9.  Simultaneous measurements of knee motion using an optical tracking system and radiostereometric analysis (RSA).

Authors:  Roy Tranberg; Tuuli Saari; Roland Zügner; Johan Kärrholm
Journal:  Acta Orthop       Date:  2011-04       Impact factor: 3.717

10.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.