Literature DB >> 16816770

Mobility of lumbar segments instrumented with a ProDisc II prosthesis: a two-year follow-up study.

Gunnar Leivseth1, Sjur Braaten, Wolfgang Frobin, Paul Brinckmann.   

Abstract

STUDY
DESIGN: Longitudinal prospective study on a sample of 41 consecutive disc prosthesis patients, covering a postoperative time period of at least 2 years.
OBJECTIVES: To document the rotational and translational range of segmental motion of patients instrumented with ProDisc II prostheses in the lumbar spine and to compare motion between instrumented and untreated adjacent segments with respect to a normative database. To discuss potential causes of the low range of rotational motion observed after instrumentation with a Prodisc II prosthesis. SUMMARY OF BACKGROUND DATA: Disc replacement is intended to restore physiologic motion and height of the affected levels. Published reports show, however, that the goal of restoring motion at the operated segment is missed in the majority of cases. The cause of this failure is unresolved.
METHODS: Rotational and translational segmental motion in the sagittal plane, disc height, and posteroanterior displacement were measured from lateral radiographic views taken standing (before surgery) and in flexion and extension (1 year and 2 years after surgery) by Distortion Compensated Roentgen Analysis (DCRA). The protocol permits to take measurements from all segments imaged on the radiographic views and compensates for variations in stature, magnification, and posture. Data from instrumented and untreated segments can be compared and related to a previously determined normative database.
RESULTS: The rotational range of motion of segments instrumented with a ProDisc II prosthesis was low, especially at L4-L5 and L5-S1. In the majority of cases, it amounted to less than 45% of the normal range. Virtually no improvement occurred between 1 and 2 years after surgery. Malalignment of the axis of rotation of the prosthesis with respect to the anatomic axis, persisting clinical symptoms, or the significant increase of intervertebral space documented after instrumentation are unlikely to cause the low range of motion. As the range of rotational motion of the untreated segments was low with respect to normal as well, it is conjectured that tissue adaptation during the preoperative symptomatic time period might have caused the postoperative motion deficit. This conjecture complies with fragmentary previous observations of a low postoperative segmental range of motion from untreated segments of fusion patients.
CONCLUSIONS: Disc replacement in the lumbar spine by a ProDisc II implant fails to restore normal segmental rotational motion in the sagittal plane, specifically at levels L4-L5 and L5-S1. As segmental motion of the untreated segments was lower than normal as well, though not quite as conspicuous as that of instrumented segments, adaptation of soft tissue taken place during the preoperative symptomatic time period is conjectured to cause the observed motion deficit. Postoperative physical therapy might be considered if restoration of a normal range of rotational motion is desired.

Entities:  

Mesh:

Year:  2006        PMID: 16816770     DOI: 10.1097/01.brs.0000224213.45330.68

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  13 in total

1.  Effects of lumbar artificial disc design on intervertebral mobility: in vivo comparison between mobile-core and fixed-core.

Authors:  Joël Delécrin; Jérôme Allain; Jacques Beaurain; Jean-Paul Steib; Jean Huppert; Hervé Chataigner; Marc Ameil; Lucie Aubourg; Jean-Michel Nguyen
Journal:  Eur Spine J       Date:  2010-12-11       Impact factor: 3.134

2.  Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance.

Authors:  Christoph J Siepe; Karsten Wiechert; Mohamed F Khattab; Andreas Korge; H Michael Mayer
Journal:  Eur Spine J       Date:  2007-01-05       Impact factor: 3.134

Review 3.  [Lumbar total disc replacement].

Authors:  D Grob
Journal:  Orthopade       Date:  2009-01       Impact factor: 1.087

Review 4.  Design concepts in lumbar total disc arthroplasty.

Authors:  Fabio Galbusera; Chiara M Bellini; Thomas Zweig; Stephen Ferguson; Manuela T Raimondi; Claudio Lamartina; Marco Brayda-Bruno; Maurizio Fornari
Journal:  Eur Spine J       Date:  2008-10-23       Impact factor: 3.134

Review 5.  Do in vivo kinematic studies provide insight into adjacent segment degeneration? A qualitative systematic literature review.

Authors:  Masoud Malakoutian; David Volkheimer; John Street; Marcel F Dvorak; Hans-Joachim Wilke; Thomas R Oxland
Journal:  Eur Spine J       Date:  2015-06-09       Impact factor: 3.134

6.  Circumferential dynamic stabilization of the lumbar spine: a biomechanical analysis.

Authors:  Wolfram Käfer; Balkan Cakir; Stefan Midderhoff; Heiko Reichel; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2014-04-11       Impact factor: 3.134

7.  Magnetic resonance morphometry of the adult normal lumbar intervertebral space.

Authors:  Apostolos H Fyllos; Dimitrios L Arvanitis; Apostolos H Karantanas; Sokratis E Varitimidis; Michael Hantes; Aristeidis H Zibis
Journal:  Surg Radiol Anat       Date:  2018-06-06       Impact factor: 1.246

8.  [Keel-based lumbar total disk replacement: Prodisc-L and Prodisc-O].

Authors:  Michael Ogon; Alexander Tuschel
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

9.  Analysis of post-operative pain patterns following total lumbar disc replacement: results from fluoroscopically guided spine infiltrations.

Authors:  Christoph J Siepe; Andreas Korge; Frank Grochulla; Christoph Mehren; H Michael Mayer
Journal:  Eur Spine J       Date:  2007-10-31       Impact factor: 3.134

10.  Does vertebral endplate morphology influence outcomes in lumbar disc arthroplasty? Part I: an initial assessment of a novel classification system of lumbar endplate morphology.

Authors:  James J Yue; Matthew E Oetgen; Jorge J Jaramillo-de la Torre; Rudolf Bertagnoli
Journal:  SAS J       Date:  2008-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.