Literature DB >> 16814644

Periprocedural and late consequences of overlapping Cypher sirolimus-eluting stents: pooled analysis of five clinical trials.

Dean J Kereiakes1, Hong Wang, Jeffrey J Popma, Richard E Kuntz, Dennis J Donohoe, Joachim Schofer, Erick Schampaert, Bernhard Meier, Martin B Leon, Jeffrey W Moses.   

Abstract

OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson & Johnson, New Brunswick, New Jersey).
BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents.
METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device.
RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction.
CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16814644     DOI: 10.1016/j.jacc.2006.02.058

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  10 in total

1.  Interventional cardiology: does stent overlap make a difference to clinical outcome?

Authors:  Antonio Colombo; Rasha Al-Lamee
Journal:  Nat Rev Cardiol       Date:  2010-07       Impact factor: 32.419

2.  Drug deposition in coronary arteries with overlapping drug-eluting stents.

Authors:  Farhad Rikhtegar; Elazer R Edelman; Ufuk Olgac; Dimos Poulikakos; Vartan Kurtcuoglu
Journal:  J Control Release       Date:  2016-07-16       Impact factor: 9.776

3.  Overlapping implantation of bioresorbable novolimus-eluting scaffolds: an observational optical coherence tomography study.

Authors:  Florian Blachutzik; Niklas Boeder; Jens Wiebe; Alessio Mattesini; Oliver Dörr; Astrid Most; Timm Bauer; Monique Tröbs; Jens Röther; Christian Schlundt; Stephan Achenbach; Christian Hamm; Holger Nef
Journal:  Heart Vessels       Date:  2016-12-21       Impact factor: 2.037

Review 4.  Mechanisms of drug-eluting stent restenosis.

Authors:  Jiro Aoki; Kengo Tanabe
Journal:  Cardiovasc Interv Ther       Date:  2020-11-21

Review 5.  Pathology of Endovascular Stents.

Authors:  Kenta Nakamura; John H Keating; Elazer Reuven Edelman
Journal:  Interv Cardiol Clin       Date:  2016-05-19

6.  The effect of the debulking by excimer laser coronary angioplasty on long-term outcome compared with drug-coating balloon: insights from optical frequency domain imaging analysis.

Authors:  Takao Sato; Keiichi Tsuchida; Sho Yuasa; Yuji Taya; Tomoyasu Koshikawa; Komei Tanaka; Satoshi Fujita; Yoshio Ikeda; Minoru Takahashi; Masaaki Okabe; Hirotaka Oda; Yoshifusa Aizawa
Journal:  Lasers Med Sci       Date:  2019-07-01       Impact factor: 3.161

7.  Potential shift from coronary bypass surgery to percutaneous coronary intervention for multivessel disease and its economic impact in the drug-eluting stent era.

Authors:  Frédéric Poulin; Stéphane Rinfret; François Gobeil
Journal:  Can J Cardiol       Date:  2007-12       Impact factor: 5.223

8.  Angiographic and 3D intravascular ultrasound assessment of overlapping bare metal stent and three different formulations of drug-eluting stents in patients with diabetes mellitus.

Authors:  Ren Kawaguchi; Manel Sabate; Dominick J Angiolillo; Pilar Jimenez-Quevedo; Nobuaki Suzuki; Cecilia Corros; Hideki Futamatsu; Fernando Alfonso; Rosana Hernandez-Antolin; Carlos Macaya; Theodore A Bass; Marco A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2007-05-31       Impact factor: 2.357

9.  Outcomes of stenting with overlapping drug-eluting stents versus overlapping drug-eluting and bare-metal stents for the treatment of diffuse coronary lesions.

Authors:  S E Kassaian; M Salarifar; M Raissi Dehkordi; M Alidoosti; E Nematipour; H R Poorhosseini; A M Hajizeinali; D Kazemisaleh; A Sharafi; M Mahmoodian; N Paydari; A V Farahani
Journal:  Cardiovasc J Afr       Date:  2010 Nov-Dec       Impact factor: 1.167

Review 10.  Sirolimus-eluting coronary stents: a review.

Authors:  Alexandre Abizaid
Journal:  Vasc Health Risk Manag       Date:  2007
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.