BACKGROUND: To evaluate the efficacy of continuous glucose monitoring system (CGMS) to detect postprandial hyperglycemia and unrecognized hypoglycemia in type 1 diabetes mellitus (DM1) patients.
METHODS: We studied 46 patients (43.4%M/56.6%F), average age of 25.9+/-12.8 years, submitted to 72 h CGMS. It were analyzed: capillary glycemia (CG) and CGMS sensor's value, glycemic excursions, postprandial hyperglycemia, asymptomatic hypoglycemia and therapeutic management after CGMS. Correlation coefficient during hypo and hyperglycemia and sensitivity/specificity were determined.
RESULTS: The mean capillary glucose values were 191.8+/-46.2mg/dl versus 190.9+/-42.1mg/dl by CGMS sensor, with no statistical difference by T-test (T=-0.6; p=0.79). The CGMS was significantly more efficient in detection of glycemic excursion than CG (p=0.001). The postprandial hyperglycemia was identified in 76.9% of diabetic patients and asymptomatic hypoglycemia was detected in 58.2% of these patients. The correlation coefficient presented no significance (p=0.16) during hypoglycemia versus during hyperglycemia (p=0.002). The CGMS sensor presented low sensitivity (79.1%) to detect hypoglycemia versus hyperglycemia (96.8%).
CONCLUSIONS: The CGMS showed to be a good method to identify postprandial hyperglycemia, to improve therapeutics management and confirmed the low sensitivity of CGMS to detect unrecognized hypoglycemia in DM1 patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16806560     DOI: 10.1016/j.diabres.2006.05.009

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  17 in total

1.  Real-time continuous glucose monitoring in the clinical setting: the good, the bad, and the practical.

Authors:  Irene Mamkin; Svetlana Ten; Sonal Bhandari; Neesha Ramchandani
Journal:  J Diabetes Sci Technol       Date:  2008-09

Review 2.  Use of technology when assessing adherence to diabetes self-management behaviors.

Authors:  Kimberly A Driscoll; Deborah Young-Hyman
Journal:  Curr Diab Rep       Date:  2014       Impact factor: 4.810

3.  Value of self-monitoring blood glucose pattern analysis in improving diabetes outcomes.

Authors:  Christopher G Parkin; Jaime A Davidson
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

Review 4.  Insulin analogues in type 1 diabetes mellitus: getting better all the time.

Authors:  Chantal Mathieu; Pieter Gillard; Katrien Benhalima
Journal:  Nat Rev Endocrinol       Date:  2017-04-21       Impact factor: 43.330

5.  Lowering physical activity impairs glycemic control in healthy volunteers.

Authors:  Catherine R Mikus; Douglas J Oberlin; Jessica L Libla; Angelina M Taylor; Frank W Booth; John P Thyfault
Journal:  Med Sci Sports Exerc       Date:  2012-02       Impact factor: 5.411

6.  Patients' perception and future acceptance of an artificial pancreas.

Authors:  Arianne C van Bon; Miriam J E Kohinor; Joost B L Hoekstra; Golo von Basum; J Hans deVries
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

Review 7.  Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

Authors:  Kazuhiro Hanazaki; Masaya Munekage; Hiroyuki Kitagawa; Tomoaki Yatabe; Eri Munekage; Mai Shiga; Hiromichi Maeda; Tsutomu Namikawa
Journal:  J Artif Organs       Date:  2016-05-03       Impact factor: 1.731

8.  Nateglinide and acarbose are comparably effective reducers of postprandial glycemic excursions in chinese antihyperglycemic agent-naive subjects with type 2 diabetes.

Authors:  Jian Zhou; Hong Li; Xiuzhen Zhang; Yongde Peng; Yifei Mo; Yuqian Bao; Weiping Jia
Journal:  Diabetes Technol Ther       Date:  2013-04-30       Impact factor: 6.118

9.  International Diabetes Federation guideline for management of postmeal glucose: a review of recommendations.

Authors:  A Ceriello; S Colagiuri
Journal:  Diabet Med       Date:  2008-10       Impact factor: 4.359

10.  Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: feasibility study testing a new model for the artificial pancreas.

Authors:  Eric Renard; Jerome Place; Martin Cantwell; Hugues Chevassus; Cesar C Palerm
Journal:  Diabetes Care       Date:  2009-10-21       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.