Literature DB >> 16798147

Carboxyhemoglobin measurement by hospitals: implications for the diagnosis of carbon monoxide poisoning.

Neil B Hampson1, Karen L Scott, Jennette L Zmaeff.   

Abstract

Most case definitions for carbon monoxide (CO) poisoning include demonstration of an elevated blood carboxyhemoglobin (COHb) concentration. Further, it is generally believed that treatment of CO poisoning is more effective when performed as soon as possible after the exposure. This suggests that a hospital's inability to measure blood COHb could lead to delayed or missed diagnosis or treatment. This study evaluated the ability of hospitals in the Pacific Northwest to measure COHb levels. The clinical laboratory of every acute care hospital in Washington, Idaho, Montana, and Alaska was surveyed regarding the ability to measure COHb levels, the method utilized and the time required. If they could not measure COHb, they were asked whether samples are sent elsewhere, the location of the referral laboratory, and time required. Results were then compared to the list of hospitals referring CO-poisoned patients to a regional center for hyperbaric oxygen therapy from 2003-2004. In the four states, only 44% of acute care hospitals have the capability to measure COHb. The remaining 56% send blood samples to other laboratories. The average time to get a result is 10 +/- 10 min in hospitals with co-oximetry and 904 +/- 1360 min in those without, a difference of 15 h (p < 0.0001). When samples are sent out, the average distance is 121 miles, often bypassing a hospital with CO-oximetry capability. Over 90% of CO-poisoned patients referred for hyperbaric treatment came from hospitals able to measure COHb. Fewer than one-half of acute care hospitals in a four-state region have the capability to measure COHb levels. This has the potential to significantly impact diagnosis or treatment of patients with acute CO poisoning.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16798147     DOI: 10.1016/j.jemermed.2005.09.010

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  6 in total

1.  Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia.

Authors:  John R Feiner; Mark D Rollins; Jeffrey W Sall; Helge Eilers; Paul Au; Philip E Bickler
Journal:  Anesth Analg       Date:  2013-03-11       Impact factor: 5.108

2.  Role of Heme Oxygenase, Leptin, Coenzyme Q10 and Trace Elements in Pre-eclamptic Women.

Authors:  Dina M Abo-Elmatty; Ehsan A Badawy; Jihan S Hussein; Somaya Abo Elela; Hoda A Megahed
Journal:  Indian J Clin Biochem       Date:  2012-06-07

3.  Multi-analyte calibration and verification of a multi-parameter laser-based pulse oximeter.

Authors:  Jonas A Pologe; Donald H Arnold; Theodore P Delianides
Journal:  J Clin Monit Comput       Date:  2021-04-19       Impact factor: 2.502

4.  Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner.

Authors:  Margot P Bickler; Laura J Rhodes
Journal:  PLoS One       Date:  2018-03-07       Impact factor: 3.240

5.  Availability of Bedside and Laboratory Testing for Carbon Monoxide Poisoning in the Upper Midwestern United States.

Authors:  Thomas Masters; Brian Willenbring; Bjorn Westgard; Jon Cole; Stephen Hendriksen; Joseph Walter; Christopher Logue; Travis Olives
Journal:  West J Emerg Med       Date:  2019-04-16

6.  Role of heme oxygenase-1, cytokines, and vascular endothelial growth factor in murine Schistosoma mansoni.

Authors:  Etimad A Huwait; Maryam A Al-Ghamdi; Maivel H Ghattas; Adel R Hinnis; Dalia A Abo El-Maaty; Dina M Abo-Elmatty; Asmaa R Abdel-Hamed
Journal:  Int J Health Sci (Qassim)       Date:  2021 Jan-Feb
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.