Literature DB >> 16794913

Current-level discrimination in the context of interleaved, multichannel stimulation in cochlear implants: effects of number of stimulated electrodes, pulse rate, and electrode separation.

Ward R Drennan1, Bryan E Pfingst.   

Abstract

The ability of cochlear implantees to detect an increment in current level at one of many stimulated electrodes was investigated. Such changes in the electric profile provide information for cochlear implantees to discriminate numerous sounds, especially vowels. In Experiment 1, sensitivity to increases in current level at one stimulation site in the electric profile decreased as the number of stimulated electrodes increased. This outcome was most likely a result of decreased stimulus levels at individual electrodes that were required to retain a comfortable loudness when the number of active electrodes was increased. Experiment 2 investigated the effects of pulse rate and separation between stimulation sites when the levels in percent of dynamic range and number of stimulated electrodes were held constant. The effect of pulse rate and electrode separation varied among listeners. The sensitivity of 6 of 9 listeners was best at the pulse rate that they used clinically. This might have been the result of adaptation to the clinical pulse rate, or listeners might have chosen their inherently best pulse rate during the clinical fitting.

Mesh:

Year:  2006        PMID: 16794913      PMCID: PMC2430008          DOI: 10.1007/s10162-006-0045-8

Source DB:  PubMed          Journal:  J Assoc Res Otolaryngol        ISSN: 1438-7573


  20 in total

1.  Speech perception as a function of electrical stimulation rate: using the Nucleus 24 cochlear implant system.

Authors:  A E Vandali; L A Whitford; K L Plant; G M Clark
Journal:  Ear Hear       Date:  2000-12       Impact factor: 3.570

2.  Nucleus 24 advanced encoder conversion study: performance versus preference.

Authors:  Margaret W Skinner; Patti L Arndt; Steven J Staller
Journal:  Ear Hear       Date:  2002-02       Impact factor: 3.570

3.  The effect of parametric variations of cochlear implant processors on speech understanding.

Authors:  P C Loizou; O Poroy; M Dorman
Journal:  J Acoust Soc Am       Date:  2000-08       Impact factor: 1.840

4.  Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy.

Authors:  Laura K Holden; Margaret W Skinner; Timothy A Holden; Marilyn E Demorest
Journal:  Ear Hear       Date:  2002-10       Impact factor: 3.570

5.  Current-level discrimination using bipolar and monopolar electrode configurations in cochlear implants.

Authors:  Ward R Drennan; Bryan E Pfingst
Journal:  Hear Res       Date:  2005-04       Impact factor: 3.208

6.  Better speech recognition with cochlear implants.

Authors:  B S Wilson; C C Finley; D T Lawson; R D Wolford; D K Eddington; W M Rabinowitz
Journal:  Nature       Date:  1991-07-18       Impact factor: 49.962

7.  Forward masked excitation patterns in multielectrode electrical stimulation.

Authors:  M Chatterjee; R V Shannon
Journal:  J Acoust Soc Am       Date:  1998-05       Impact factor: 1.840

8.  Patterns of neural degeneration in the human cochlea and auditory nerve: implications for cochlear implantation.

Authors:  J B Nadol
Journal:  Otolaryngol Head Neck Surg       Date:  1997-09       Impact factor: 3.497

9.  Long-term sensorineural hearing loss induces functional changes in the rat auditory nerve.

Authors:  Robert K Shepherd; Lloyd A Roberts; Antonio G Paolini
Journal:  Eur J Neurosci       Date:  2004-12       Impact factor: 3.386

10.  Forward masking patterns produced by intracochlear electrical stimulation of one and two electrode pairs in the human cochlea.

Authors:  H H Lim; Y C Tong; G M Clark
Journal:  J Acoust Soc Am       Date:  1989-09       Impact factor: 1.840

View more
  4 in total

1.  A psychophysical method for measuring spatial resolution in cochlear implants.

Authors:  Mahan Azadpour; Colette M McKay
Journal:  J Assoc Res Otolaryngol       Date:  2011-10-15

2.  Effects of carrier pulse rate and stimulation site on modulation detection by subjects with cochlear implants.

Authors:  Bryan E Pfingst; Li Xu; Catherine S Thompson
Journal:  J Acoust Soc Am       Date:  2007-04       Impact factor: 1.840

3.  Current-level discrimination and spectral profile analysis in multi-channel electrical stimulation.

Authors:  Matthew J Goupell; Bernhard Laback; Piotr Majdak; Wolf-Dieter Baumgartner
Journal:  J Acoust Soc Am       Date:  2008-11       Impact factor: 1.840

4.  Envelope Interactions in Multi-Channel Amplitude Modulation Frequency Discrimination by Cochlear Implant Users.

Authors:  John J Galvin; Sandra I Oba; Deniz Başkent; Monita Chatterjee; Qian-Jie Fu
Journal:  PLoS One       Date:  2015-10-02       Impact factor: 3.240

  4 in total