Literature DB >> 16781400

The Zweymüller threaded cup: a choice in revision? Migration analysis and follow-up after 6 years.

Jörg Hartmut Schröder1, Georg Matziolis, Jens Tuischer, Dirk Leutloff, Georg Norbert Duda, Carsten Perka.   

Abstract

Excellent long-term results are reported for threaded cups with an osteointegrable surface in primary interventions. So far, little data are available on the use of such implants in revision cases. We investigated 30 loosened Aesculap PM threaded cups (Tuttlingen, Germany) with a smooth surface, revised with a conical, corundum-blasted Zweymüller threaded cup (Zweymüller Alloclassic CSF cup, Zimmer, Warsaw, Ind). Aseptic radiological loosening was seen in 8% of cases, and a survival rate of 95% was achieved after 6.1 years. Average migration was 1.4 mm cranially and 0.7 mm medially. The Harris hip score improved from 42 points preoperatively to 75 points at follow-up. Good medium-term results are possible after revision using a threaded cup with an osteointegrable surface, but not if segmental acetabular margin defects are present.

Entities:  

Mesh:

Year:  2006        PMID: 16781400     DOI: 10.1016/j.arth.2005.05.029

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

Review 1.  [Comparison of different cup revision systems].

Authors:  K Trieb
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

2.  Case reports: fractures of threaded cups: rare complications of a well-established implant.

Authors:  Arnd T Hoburg; Manav Mehta; Stephan Tohtz; Carsten Perka
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

3.  High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.

Authors:  Nikolaos A Christodoulou; Konstantinos P Dialetis; Athanasios N Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-01-05       Impact factor: 4.176

4.  30-Years of experience with the cementless implanted Alloclassic CSF screw cup total hip arthroplasty system - An ultra-long-term follow-up.

Authors:  Lorenz Pisecky; Günter Hipmair; Bernhard Schauer; Nikolaus Böhler
Journal:  J Orthop       Date:  2019-02-28

5.  Straight stem and threaded cup in patients under 60 years of age: 28.8-30.2 years of follow-up.

Authors:  L Pisecky; J Allerstorfer; B Schauer; G Hipmair; R Hochgatterer; N Böhler; T Gotterbarm; M C Klotz
Journal:  J Orthop Surg Res       Date:  2020-11-26       Impact factor: 2.359