Literature DB >> 16772897

Anterior segment measurements using digital photography: a simple technique.

R Cameron VanRoekel1, Kraig S Bower, Jenna M Burka, Robin S Howard.   

Abstract

PURPOSE: The purpose of this study is to describe a simple method of measuring anterior segment lesions from digital slit lamp images and confirm reliability of the technique.
METHODS: Ten reference photos were taken of a PD ruler, refocusing on the ruler for each photo. Using Adobe Photoshop, the number of pixels per millimeter squared (area) and 1 mm (linear) were recorded for each photo. An Excel spreadsheet was set up to convert pixels to millimeters and millimeters squared. Interrater reliability was determined by two observers who independently calculated the area of 69 epithelial defects. A Bland and Altman plot was used to demonstrate the agreement between the two doctors.
RESULTS: Interrater reliability was excellent as measured by an intraclass correlation coefficient (ICC 2,1) = 0.99. From the Bland and Altman plot it was determined that in 95% of cases, the area of the epithelial defect measured by provider 2 may be as much as 1.17 mm less than or 1.09 mm greater than that measured by provider 1.
CONCLUSION: This simple method, which allows accurate measurements from digital images using common off-the-shelf software, is a valuable tool for clinical documentation as well as for research purposes.

Entities:  

Mesh:

Year:  2006        PMID: 16772897     DOI: 10.1097/01.opx.0000221404.40296.ba

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  6 in total

1.  Triple subconjunctival bevacizumab injection for early corneal recurrent pterygium: one-year follow-up.

Authors:  Angel Nava-Castañeda; Isabel Ulloa-Orozco; Lilia Garnica-Hayashi; Joaquín Hernandez-Orgaz; Maria Carmen Jimenez-Martinez; Yonathan Garfias
Journal:  J Ocul Pharmacol Ther       Date:  2014-11-04       Impact factor: 2.671

2.  Novel Image-Based Analysis for Reduction of Clinician-Dependent Variability in Measurement of the Corneal Ulcer Size.

Authors:  Tapan P Patel; N Venkatesh Prajna; Sina Farsiu; Nita G Valikodath; Leslie M Niziol; Lakshey Dudeja; Kyeong Hwan Kim; Maria A Woodward
Journal:  Cornea       Date:  2018-03       Impact factor: 2.651

3.  Evaluation of fungal keratitis using a newly developed computer program, Optscore, for grading digital corneal photographs.

Authors:  Christine M Toutain-Kidd; Travis C Porco; Eric M Kidd; M Srinivasan; Namperumalsamy V Prajna; Nisha Acharya; Thomas Lietman; Michael E Zegans
Journal:  Ophthalmic Epidemiol       Date:  2014-02       Impact factor: 1.648

4.  Open-Source Automatic Segmentation of Ocular Structures and Biomarkers of Microbial Keratitis on Slit-Lamp Photography Images Using Deep Learning.

Authors:  Jessica Loo; Matthias F Kriegel; Megan M Tuohy; Kyeong Hwan Kim; Venkatesh Prajna; Maria A Woodward; Sina Farsiu
Journal:  IEEE J Biomed Health Inform       Date:  2021-01-05       Impact factor: 5.772

5.  Single and multiple injections of subconjunctival ranibizumab for early, recurrent pterygium.

Authors:  Volkan Hurmeric; Pravin Vaddavalli; Anat Galor; Victor L Perez; Janika San Roman; Sonia H Yoo
Journal:  Clin Ophthalmol       Date:  2013-03-04

6.  Use of 'U-shaped tool for follow up of corneal ulcer cases in the COVID-19 pandemic.

Authors:  Rahul K Bafna; Abhijeet Beniwal; Nidhi Kalra; Suman Lata; Mohamed Ibrahime Asif; Namrata Sharma
Journal:  Indian J Ophthalmol       Date:  2020-10       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.