Literature DB >> 16772670

Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection.

Daniele Giansanti1, Giovanni Maccioni.   

Abstract

A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s for start and stop detection.

Mesh:

Year:  2006        PMID: 16772670     DOI: 10.1088/0967-3334/27/8/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  8 in total

1.  Validity of accelerometry in assessing the duration of the sit-to-stand movement.

Authors:  Wim G M Janssen; Johannes B J Bussmann; Herwin L D Horemans; Henk J Stam
Journal:  Med Biol Eng Comput       Date:  2008-07-15       Impact factor: 2.602

2.  Trunk angular kinematics during slip-induced backward falls and activities of daily living.

Authors:  Jian Liu; Thurmon E Lockhart
Journal:  J Biomech Eng       Date:  2014-10       Impact factor: 2.097

3.  Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects.

Authors:  Daniele Giansanti; Giovanni Maccioni; Francesco Benvenuti; Velio Macellari
Journal:  Med Biol Eng Comput       Date:  2007-07-25       Impact factor: 2.602

4.  Test-retest reliability of a pendant-worn sensor device in measuring chair rise performance in older persons.

Authors:  Wei Zhang; G Ruben H Regterschot; Hana Schaabova; Heribert Baldus; Wiebren Zijlstra
Journal:  Sensors (Basel)       Date:  2014-05-16       Impact factor: 3.576

5.  The Instrumented Sit-to-Stand Test (iSTS) Has Greater Clinical Relevance than the Manually Recorded Sit-to-Stand Test in Older Adults.

Authors:  Rob C van Lummel; Stefan Walgaard; Andrea B Maier; Erik Ainsworth; Peter J Beek; Jaap H van Dieën
Journal:  PLoS One       Date:  2016-07-08       Impact factor: 3.240

6.  Older Adults with Weaker Muscle Strength Stand up from a Sitting Position with More Dynamic Trunk Use.

Authors:  Rob C van Lummel; Jordi Evers; Martijn Niessen; Peter J Beek; Jaap H van Dieën
Journal:  Sensors (Basel)       Date:  2018-04-17       Impact factor: 3.576

7.  Thigh-Derived Inertial Sensor Metrics to Assess the Sit-to-Stand and Stand-to-Sit Transitions in the Timed Up and Go (TUG) Task for Quantifying Mobility Impairment in Multiple Sclerosis.

Authors:  Harry J Witchel; Cäcilia Oberndorfer; Robert Needham; Aoife Healy; Carina E I Westling; Joseph H Guppy; Jake Bush; Jens Barth; Chantal Herberz; Daniel Roggen; Björn M Eskofier; Waqar Rashid; Nachiappan Chockalingam; Jochen Klucken
Journal:  Front Neurol       Date:  2018-09-14       Impact factor: 4.003

8.  Sit-To-Stand Movement Evaluated Using an Inertial Measurement Unit Embedded in Smart Glasses-A Validation Study.

Authors:  Justine Hellec; Frédéric Chorin; Andrea Castagnetti; Serge S Colson
Journal:  Sensors (Basel)       Date:  2020-09-04       Impact factor: 3.576