Literature DB >> 18626677

Validity of accelerometry in assessing the duration of the sit-to-stand movement.

Wim G M Janssen1, Johannes B J Bussmann, Herwin L D Horemans, Henk J Stam.   

Abstract

Accelerometry is frequently used in movement analysis to assess body postures and motions. Here, we assessed the validity of ambulatory accelerometric measurement of the sit-to-stand (STS) movement duration. We compared accelerometric and opto-electronic assessment of the STS movement duration under four conditions (comfortable, slow, fast movement and exaggerated trunk flexion) with six healthy subjects and six subjects with stroke who performed movements six times under each condition. Accelerometric and opto-electronic data of STS movement duration were strongly related (r = 0.98). Accelerometry showed a fixed bias of 0.07 s (95% CI 0.008, 0.141) in healthy subjects and 0.32 s (95% CI 0.223, 0.422) in stroke subjects. In healthy subjects, a significant negative proportional bias of 0.1 was detected (95% CI -0.160, -0.032). Accelerometry showed discriminative validity in comparing stroke subjects to healthy subjects, and in comparing speed conditions. Our results indicate that accelerometry can provide valid data on the STS movement duration, furthermore during its use additional information on the STS movement, such as balance control, can be recorded.

Entities:  

Mesh:

Year:  2008        PMID: 18626677     DOI: 10.1007/s11517-008-0366-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  40 in total

1.  Predicting discharge destination for patients with severe motor stroke: important functional tasks.

Authors:  P J Mokler; R Sandstrom; M Griffin; L Farris; C Jones
Journal:  Neurorehabil Neural Repair       Date:  2000       Impact factor: 3.919

2.  Everyday physical activity in adolescents and young adults with meningomyelocele as measured with a novel activity monitor.

Authors:  H J van den Berg-Emons; J B Bussmann; A S Brobbel; M E Roebroeck; J van Meeteren; H J Stam
Journal:  J Pediatr       Date:  2001-12       Impact factor: 4.406

3.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems.

Authors:  Ruth E Mayagoitia; Anand V Nene; Peter H Veltink
Journal:  J Biomech       Date:  2002-04       Impact factor: 2.712

4.  Repeated chair stands as a measure of lower limb strength in sexagenarian women.

Authors:  Erick K McCarthy; Michael A Horvat; Philip A Holtsberg; Joseph M Wisenbaker
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2004-11       Impact factor: 6.053

Review 5.  Bivariate line-fitting methods for allometry.

Authors:  David I Warton; Ian J Wright; Daniel S Falster; Mark Westoby
Journal:  Biol Rev Camb Philos Soc       Date:  2006-03-30

6.  Control of body mass transfer as a function of speed of ascent in sit-to-stand.

Authors:  Y C Pai; M W Rogers
Journal:  Med Sci Sports Exerc       Date:  1990-06       Impact factor: 5.411

7.  Sit-to-stand test for measuring performance of lower extremity muscles.

Authors:  R W Bohannon
Journal:  Percept Mot Skills       Date:  1995-02

8.  An analysis of sit-to-stand movements.

Authors:  T Kotake; N Dohi; T Kajiwara; N Sumi; Y Koyama; T Miura
Journal:  Arch Phys Med Rehabil       Date:  1993-10       Impact factor: 3.966

9.  Reliability of measurements of body center-of-mass momentum during sit-to-stand in healthy adults.

Authors:  T A Hanke; Y C Pai; M W Rogers
Journal:  Phys Ther       Date:  1995-02

10.  A 30-s chair-stand test as a measure of lower body strength in community-residing older adults.

Authors:  C J Jones; R E Rikli; W C Beam
Journal:  Res Q Exerc Sport       Date:  1999-06       Impact factor: 2.500

View more
  11 in total

1.  Movement analysis by accelerometry of newborns and infants for the early detection of movement disorders due to infantile cerebral palsy.

Authors:  Franziska Heinze; Katharina Hesels; Nico Breitbach-Faller; Thomas Schmitz-Rode; Catherine Disselhorst-Klug
Journal:  Med Biol Eng Comput       Date:  2010-05-06       Impact factor: 2.602

2.  Time measurement characterization of stand-to-sit and sit-to-stand transitions by using a smartphone.

Authors:  Hernán A González Rojas; Pedro Chaná Cuevas; Enrique E Zayas Figueras; Salvador Cardona Foix; Antonio J Sánchez Egea
Journal:  Med Biol Eng Comput       Date:  2017-10-23       Impact factor: 2.602

3.  An accelerometer-based method for estimating fluidity in the sit-to-walk task.

Authors:  Tomoyuki Asakura; Hikaru Hagiwara; Yoshiyuki Miyazawa; Shigeru Usuda
Journal:  J Phys Ther Sci       Date:  2015-11-30

4.  An evaluation of the 30-s chair stand test in older adults: frailty detection based on kinematic parameters from a single inertial unit.

Authors:  Nora Millor; Pablo Lecumberri; Marisol Gómez; Alicia Martínez-Ramírez; Mikel Izquierdo
Journal:  J Neuroeng Rehabil       Date:  2013-08-01       Impact factor: 4.262

5.  The validity of an accelerometer-based method for estimating fluidity in the sit-to-walk task in a community setting.

Authors:  Tomoyuki Asakura; Yoshiyuki Miyazawa; Shigeru Usuda
Journal:  J Phys Ther Sci       Date:  2017-01-30

6.  Fatigue Detection during Sit-To-Stand Test Based on Surface Electromyography and Acceleration: A Case Study.

Authors:  Cristina Roldán Jiménez; Paul Bennett; Andrés Ortiz García; Antonio I Cuesta Vargas
Journal:  Sensors (Basel)       Date:  2019-09-27       Impact factor: 3.576

7.  Accelerometry-Based Metrics to Evaluate the Relative Use of the More Affected Arm during Daily Activities in Adults Living with Cerebral Palsy.

Authors:  Isabelle Poitras; Jade Clouâtre; Alexandre Campeau-Lecours; Catherine Mercier
Journal:  Sensors (Basel)       Date:  2022-01-28       Impact factor: 3.576

8.  Thigh-Derived Inertial Sensor Metrics to Assess the Sit-to-Stand and Stand-to-Sit Transitions in the Timed Up and Go (TUG) Task for Quantifying Mobility Impairment in Multiple Sclerosis.

Authors:  Harry J Witchel; Cäcilia Oberndorfer; Robert Needham; Aoife Healy; Carina E I Westling; Joseph H Guppy; Jake Bush; Jens Barth; Chantal Herberz; Daniel Roggen; Björn M Eskofier; Waqar Rashid; Nachiappan Chockalingam; Jochen Klucken
Journal:  Front Neurol       Date:  2018-09-14       Impact factor: 4.003

9.  Sit-To-Stand Movement Evaluated Using an Inertial Measurement Unit Embedded in Smart Glasses-A Validation Study.

Authors:  Justine Hellec; Frédéric Chorin; Andrea Castagnetti; Serge S Colson
Journal:  Sensors (Basel)       Date:  2020-09-04       Impact factor: 3.576

10.  An Experimental Study on the Validity and Reliability of a Smartphone Application to Acquire Temporal Variables during the Single Sit-to-Stand Test with Older Adults.

Authors:  Diogo Luís Marques; Henrique Pereira Neiva; Ivan Miguel Pires; Eftim Zdravevski; Martin Mihajlov; Nuno M Garcia; Juan Diego Ruiz-Cárdenas; Daniel Almeida Marinho; Mário Cardoso Marques
Journal:  Sensors (Basel)       Date:  2021-03-15       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.