Literature DB >> 16771553

Fabrication of a planar-form screen-printed solid electrolyte modified Ag/AgCl reference electrode for application in a potentiometric biosensor.

Wei-Yin Liao1, Tse-Chuan Chou.   

Abstract

This study features the fabrication of a planar-form, solid electrolyte modified, (PSEM) Ag/AgCl reference electrode using a screen-printing method. The PSEM Ag/AgCl reference electrode uses agar gel as the inner electrolyte and chloroprene rubber for the liquid junction and insulator. These common low-cost materials and the simple fabrication processes involved render the proposed reference electrode an ideal candidate for cost-efficient mass production. It is shown that the developed reference electrode is insensitive to most of the physiologically important ionic species, including Na+, K+, Li+, Ca2+, NH4+, and Cl-, under continuous measurement conditions. Moreover, as with conventional commercial reference electrodes, the proposed reference electrode exhibits a reversible response, which is maintained until the agar gel dries out. The PSEM Ag/AgCl reference electrode is integrated with an iridium oxide modified Pt-based pH indicator electrode to form a chip-type pH biosensor. The performance of this biosensor is consistent with that obtained from a pH meter based on a macroscopic commercial Ag/AgCl reference electrode. The experimental results confirm that the proposed biosensor is capable of providing precise pH measurements of various real samples. Accordingly, the PSEM Ag/AgCl reference electrode presented in this study provides a viable alternative to the macroscopic Ag/AgCl reference electrode used in many conventional chip-based pH sensors.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16771553     DOI: 10.1021/ac051562+

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

2.  A flexible Ag/AgCl micro reference electrode based on a parylene tube structure.

Authors:  Zhiguo Zhao; Hongen Tu; Eric Gr Kim; Bonnie F Sloane; Yong Xu
Journal:  Sens Actuators B Chem       Date:  2017-03-02       Impact factor: 7.460

3.  Real-time telemetry system for amperometric and potentiometric electrochemical sensors.

Authors:  Wei-Song Wang; Hong-Yi Huang; Shu-Chun Chen; Kuo-Chuan Ho; Chia-Yu Lin; Tse-Chuan Chou; Chih-Hsien Hu; Wen-Fong Wang; Cheng-Feng Wu; Ching-Hsing Luo
Journal:  Sensors (Basel)       Date:  2011-09-02       Impact factor: 3.576

Review 4.  Microfabricated reference electrodes and their biosensing applications.

Authors:  M Waleed Shinwari; David Zhitomirsky; Imran A Deen; P R Selvaganapathy; M Jamal Deen; D Landheer
Journal:  Sensors (Basel)       Date:  2010-03-02       Impact factor: 3.576

5.  RuO₂ pH Sensor with Super-Glue-Inspired Reference Electrode.

Authors:  Wade Lonsdale; Magdalena Wajrak; Kamal Alameh
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.