An experimental comparison of flat-panel detector performance for direct and indirect systems (initial experiences and physical evaluation).

Tsutomu Gomi1, Kichirou Koshida, Tosiaki Miyati, Jun Miyagawa, Hiroshi Hirano.   

Abstract

The purpose of this work was to compare direct and indirect detectors in terms of their system linearity, presampled modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ), and power spectrum. Measurements were made on two flat-panel detectors, GE Revolution XR/d (indirect) and Shimadzu Safire (direct) radiographic techniques. The system linearity of the systems was measured using a time-scale method. The MTF of the systems was measured using an edge method. The WS of the systems was determined for a variable range of exposure levels by two-dimensional Fourier analysis. The NEQ was assessed from the measured MTF, WS, and estimated ideal signal-to-noise ratios. Power spectrum analyzed the chest phantom within artificial lesions. System linearity was excellent for the direct systems. For the direct system, the MTF was found to be significantly higher than that for the indirect systems. For the direct system, the WS was relatively uniform across all frequencies. In comparison, the indirect system exhibited a drop in the WS at high frequencies. At lower frequencies, the NEQ for the indirect system was noticeably higher than for the direct system. Power spectrum for the direct system was relatively flat and similar to that for white noise. The indirect system exhibited significant reduction at high spatial frequencies. In general, the direct systems exhibit improved image quality over indirect systems at comparable exposure dose.

Entities:  

Mesh:

Year:  2006        PMID: 16763929      PMCID: PMC3045156          DOI: 10.1007/s10278-006-0634-4

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  9 in total

1.  Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.

Authors:  C E Floyd; R J Warp; J T Dobbins; H G Chotas; A H Baydush; R Vargas-Voracek; C E Ravin
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

2.  Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications.

Authors:  P R Granfors; R Aufrichtig
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

3.  An experimental comparison of detector performance for computed radiography systems.

Authors:  Ehsan Samei; Michael J Flynn
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

4.  A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography.

Authors:  J H Launders; S M Kengyelics; A R Cowen
Journal:  Med Phys       Date:  1998-06       Impact factor: 4.071

5.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

6.  Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector.

Authors:  W Zhao; I Blevis; S Germann; J A Rowlands; D Waechter; Z Huang
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

Review 7.  X-ray detectors for digital radiography.

Authors:  M J Yaffe; J A Rowlands
Journal:  Phys Med Biol       Date:  1997-01       Impact factor: 3.609

8.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; J M Boudry; I A Cunningham
Journal:  Med Phys       Date:  1997-01       Impact factor: 4.071

9.  Basic imaging properties of a computed radiographic system with photostimulable phosphors.

Authors:  H Fujita; K Ueda; J Morishita; T Fujikawa; A Ohtsuka; T Sai
Journal:  Med Phys       Date:  1989 Jan-Feb       Impact factor: 4.071

  9 in total
  2 in total

1.  Structural noise from automatic exposure control device and its relationship to X-ray tube voltage used for calibration of a flat-panel detector system.

Authors:  Masayoshi Mizuta; Hiroyuki Akazawa; Toshifumi Kasai; Shigeru Sanada; Shuji Abe; Shigeki Mitou
Journal:  Radiol Phys Technol       Date:  2011-08-23

2.  Efficiency and reporting confidence analysis of sequential dual-energy subtraction for thoracic x-ray examinations.

Authors:  Mehmet Can Gezer; Oktay Algin; Aytac Durmaz; Halil Arslan
Journal:  Qatar Med J       Date:  2019-09-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.