Literature DB >> 16754067

A comparison of balloon- and self-expanding stents.

.   

Abstract

This paper summarizes some of the key differences between self-expanding and balloon-expanding stents, aligning engineering and design differences with clinical performance. While neither type of stent can be considered universally superior, the differences are significant enough to make each type more appropriate in specific circumstances. Many of the differences concern long-term outcome, for which there is still insufficient data.

Entities:  

Year:  2002        PMID: 16754067     DOI: 10.1080/136457002760273386

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  14 in total

1.  Assessment of annular distensibility in the aortic valve.

Authors:  John O'Dea; David J Nolan
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-13

2.  Intra- and inter-observer reliability of combined segmental measurement techniques for predicting immediate post-deployment intraluminal tracheal stent length in dogs.

Authors:  Thomas A Monaco; Jim A Taylor; Anke Langenbach; Sebastian Gordon; Eric Vance
Journal:  Can Vet J       Date:  2014-05       Impact factor: 1.008

3.  Restenosis after stenting in symptomatic vertebral arterial orifice disease and considerations for better outcome.

Authors:  Jun Young Chang; Hyun Park; Oki Kwon; Moon-Ku Han
Journal:  Interv Neuroradiol       Date:  2017-01-06       Impact factor: 1.610

4.  Does endovascular repair of post-traumatic thoracic vascular injury of the subclavian/axillary arteries followed by brachial plexus injury improve outcome?

Authors:  Darpanarayan Hazra; Albert Abhinay Kota; Sam Pon Raj; Prabhu Premkumar; Andrew Dheepak Selvaraj; Sunil Agarwal; Binu Prathap Thomas
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-12-03

5.  Stenting for peripheral artery disease of the lower extremities: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-09-01

6.  Effect of flow diverter porosity on intraaneurysmal blood flow.

Authors:  Luca Augsburger; Mohamed Farhat; Philippe Reymond; Edouard Fonck; Zsolt Kulcsar; Nikos Stergiopulos; Daniel A Rüfenacht
Journal:  Klin Neuroradiol       Date:  2009-08-23

7.  Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment.

Authors:  Wan Naimah Wan Ab Naim; Zhonghua Sun; Yih Miin Liew; Bee Ting Chan; Shirley Jansen; Jing Lei; Poo Balan Ganesan; Shahrul Amry Hashim; Ganiga Srinivasaiah Sridhar; Einly Lim
Journal:  Quant Imaging Med Surg       Date:  2021-05

8.  Stent Placement for Acute Superior Mesenteric Artery Occlusion Associated with Type B Aortic Dissection.

Authors:  Kazushi Suzuki; Masashi Shimohira; Takuya Hashizume; Yuta Shibamoto
Journal:  Case Rep Vasc Med       Date:  2015-05-25

9.  A new structure-property connection in the skeletal elements of the marine sponge Tethya aurantia that guards against buckling instability.

Authors:  Michael A Monn; Haneesh Kesari
Journal:  Sci Rep       Date:  2017-01-04       Impact factor: 4.379

10.  Self expandable stent application to prevent limb occlusion in external iliac artery during endovascular aneurysm repair.

Authors:  Jae Hoon Lee; Ki Hyuk Park
Journal:  Ann Surg Treat Res       Date:  2016-08-29       Impact factor: 1.859

View more