Literature DB >> 16750438

Long-term tissue response to bioabsorbable poly-L-lactide and metallic screws: an experimental study.

Harri Pihlajamäki1, Ole Böstman, Olli Tynninen, Outi Laitinen.   

Abstract

Late, clinically manifest, adverse inflammatory reactions have sometimes occurred after the use of slowly degrading bioabsorbable poly-l-lactide (PLLA) devices in clinical series of bone fixation. In this study, long-term tissue response to bioabsorbable fracture fixation screws made of poly-l-lactide and to similar metallic screws in cancellous bone was examined and compared with intact bone. The postoperative evaluation of the rabbit femora was performed by using plain radiography, microradiography, histology, histomorphometry, and oxytetracycline labeling studies. The follow-up times were 36 and 51 months in groups of 15 and 14 rabbits, respectively. A walling-off response by formation of trabecular bone which outlined the screw profile was observed in the PLLA and metallic groups both. Connective tissue between this bone front and the implant was seen only in the PLLA group. There was no difference in the thickness of the layer between the two follow-up groups. Between the surgically handled femora and the intact control bone, there was no statistically significant difference in the amount of trabecular bone. The osteoid formation activity in the tissue-implant interface showed no differences between the groups. However, active osteoblasts were visible only in the PLLA group. The amount of birefringent PLLA material diminished between the 36-month and the 51-month follow-up groups. Within the follow-up times of this study, both the PLLA screws and the metallic screws were rather inert. Also, long-term walling-off was a typical response to both PLLA and metallic screws in cancellous bone. PLLA screws did not evoke any osteostimulatory reaction over the long-term follow-up. The findings clearly demonstrated that the overall degradation process of PLLA was very slow and accompanied by fibrous tissue formation. Macrophage activity seemed to be related to the slow degradation process of PLLA and might be associated with the formation of connective tissue replacing the original implant. The results of this study showed no significant differences between the bioabsorbable PLLA screws and the metallic screws in biocompatibility, and no signs of inflammatory foreign-body reactions occurred during the follow-up.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16750438     DOI: 10.1016/j.bone.2006.04.009

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  12 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

2.  Is the etiology of pretibial cyst formation after absorbable interference screw use related to a foreign body reaction?

Authors:  Guillem Gonzalez-Lomas; Ryan T Cassilly; Fabrizio Remotti; William N Levine
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

3.  CALAXO osteoconductive interference screw: the value of postmarket surveillance.

Authors:  Charles L Cox; Kelly C Homlar; James L Carey; Kurt P Spindler
Journal:  J Surg Orthop Adv       Date:  2010

4.  Optimizing injectable poly-L-lactic acid administration for soft tissue augmentation: The rationale for three treatment sessions.

Authors:  Ute Bauer; Miles H Graivier
Journal:  Can J Plast Surg       Date:  2011

5.  Do newer-generation bioabsorbable screws become incorporated into bone at two years after ACL reconstruction with patellar tendon graft?: A cohort study.

Authors:  Charles L Cox; Kurt P Spindler; James P Leonard; Brent J Morris; Warren R Dunn; Emily K Reinke
Journal:  J Bone Joint Surg Am       Date:  2014-02-05       Impact factor: 5.284

6.  Bone screws have advantages in repair of experimental osteochondral fragments.

Authors:  Michihaya Kono; Ryuji Mori; Yuji Uchio
Journal:  Clin Orthop Relat Res       Date:  2011-11-12       Impact factor: 4.176

7.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

8.  Tissue restoration after implantation of polyglycolide, polydioxanone, polylevolactide, and metallic pins in cortical bone: an experimental study in rabbits.

Authors:  Harri K Pihlajamäki; Sari T Salminen; Olli Tynninen; Ole M Böstman; Outi Laitinen
Journal:  Calcif Tissue Int       Date:  2010-05-22       Impact factor: 4.333

9.  Vancomycin containing PLLA/β-TCP controls experimental osteomyelitis in vivo.

Authors:  Berna Kankilic; Elif Bilgic; Petek Korkusuz; Feza Korkusuz
Journal:  J Orthop Surg Res       Date:  2014-11-19       Impact factor: 2.359

10.  Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis.

Authors:  Mathieu Manassero; Adeline Decambron; Bui Truong Huu Thong; Véronique Viateau; Morad Bensidhoum; Hervé Petite
Journal:  J Vis Exp       Date:  2016-10-12       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.