Use of peripheral dose data from uniform dynamic multileaf collimation fields to estimate out-of-field organ dose in patients treated employing sliding window intensity-modulated radiotherapy.

Shamurailatpam Dayananda Sharma1, Ritu Raj Upreti, Deepak Dattatray Deshpande.   

Abstract

Peripheral doses (PD) from uniform dynamic multileaf collimation (DMLC) fields were measured for 6 MV x-rays on a Varian linear accelerator using a 0.6 cc ionization chamber inserted at 5 cm depth into a 35 x 35 x 105 cm3 plastic water phantom. PD measurements were also carried out under identical conditions for seven patients treated for head and neck and cervical cancer employing sliding window intensity-modulated radiotherapy (IMRT). The measured PD from these patient-specific intensity-modulated beams (IMBs) were compared with the corresponding data from uniform DMLC fields having similar jaws setting. The measured PD per monitor unit (PD/MU) decreases almost exponentially with out-of-field distance for all uniform DMLC and static fields. For the same strip field width of 1.2 cm, uniform DMLC fields with a larger size of 14 x 22 cm2 deliver an average of 3.51 (SD = 0.51) times higher PD/MU at all out-of-field distances compared to 6 x 6 cm2. Similar to uniform DMLC fields, PD/MU measured from different patient-specific IMBs was found to decrease almost exponentially with out-of-field distance and increase with increase in field dimension. PD per MU from uniform DMLC fields and patient-specific IMBs having similar jaws setting shows good agreement (+/-7%) except at the most proximal distance, where a variation of more than 10% (maximum 15%) was observed. Our study shows that PD data generated from uniform DMLC fields can be used as baseline data to estimate out-of-field critical organ or whole-body dose in patients treated employing sliding window IMRT if an appropriate correction factor for field dimension is applied. The whole-body dose information can be used to estimate the possible increase in risk of fatal secondary malignancy in patients treated employing sliding window IMRT.

Entities:  

Mesh:

Year:  2006        PMID: 16723779     DOI: 10.1088/0031-9155/51/11/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments.

Authors:  Erika Di Betta; Laura Fariselli; Achille Bergantin; Federica Locatelli; Antonella Del Vecchio; Sara Broggi; Maria Luisa Fumagalli
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

2.  EURADOS strategic research agenda: vision for dosimetry of ionising radiation.

Authors:  W Rühm; E Fantuzzi; R Harrison; H Schuhmacher; F Vanhavere; J Alves; J F Bottollier Depois; P Fattibene; Ž Knežević; M A Lopez; S Mayer; S Miljanić; S Neumaier; P Olko; H Stadtmann; R Tanner; C Woda
Journal:  Radiat Prot Dosimetry       Date:  2015-03-09       Impact factor: 0.972

3.  Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques.

Authors:  Jihyung Yoon; David Heins; Xiaodong Zhao; Mary Sanders; Rui Zhang
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

Review 4.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

5.  Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy.

Authors:  Michael L Taylor; Tomas Kron
Journal:  J Med Phys       Date:  2011-04

6.  Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques.

Authors:  Ming X Jia; Xu Zhang; Ce Yin; Ge Feng; Na Li; Song Gao; Da W Liu
Journal:  Radiat Oncol       Date:  2014-02-21       Impact factor: 3.481

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.