Application of contrast-to-noise ratio in optimizing beam quality for digital chest radiography: comparison of experimental measurements and theoretical simulations.

P Doyle1, C J Martin, D Gentle.   

Abstract

The contrast-to-noise ratio (CNR) has been employed in optimizing beam quality for imaging a chest phantom using digital radiography. The relationship between CNR and tube potential has been studied for regions of different attenuations representing the lung, heart and abdomen, and a figure of merit (FOM) incorporating effective dose has been calculated to enable dose performance to be included. Direct measurements of imaging performance have been compared with simulations based on a model representing object attenuations. The study has shown reasonable agreement between measurements of CNR and calculated values. The CNR values in the lung and heart regions are higher at 60-80 kV, while those for the abdomen are higher at 90-110 kV. Incorporating a 0.2 mm copper filter has minimal effect on image quality and the FOM is higher because of the reduction in dose. For imaging the heart and abdomen, performance was improved through use of a technique to remove scatter, with an air-gap technique giving a higher FOM because of the lower dose. The CNR and FOM can provide useful quantities for evaluating imaging performance to optimize beam quality for different imaging tasks.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16723777     DOI: 10.1088/0031-9155/51/11/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system.

Authors:  Paula Toroi; Federica Zanca; Kenneth C Young; Chantal van Ongeval; Guy Marchal; Hilde Bosmans
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 5.315

2.  Characterization of a high-energy in-line phase contrast tomosynthesis prototype.

Authors:  Di Wu; Aimin Yan; Yuhua Li; Molly D Wong; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

3.  Optimisation of radiological protocols for chest imaging using computed radiography and flat-panel X-ray detectors.

Authors:  G Compagnone; M Casadio Baleni; E Di Nicola; M Valentino; M Benati; L F Calzolaio; N Oberhofer; E Fabbri; S Domenichelli; L Barozzi
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

4.  Dependence of radiographic sensitivity of CR imaging plate on X-ray tube voltage.

Authors:  Yoshiyuki Asai; Masanobu Uemura; Masao Matsumoto; Hitoshi Kanamori
Journal:  Radiol Phys Technol       Date:  2007-12-11

5.  Modeling, validation and application of a mathematical tissue-equivalent breast phantom for linear slot-scanning digital mammography.

Authors:  K Hussein; C L Vaughan; T S Douglas
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

6.  Initial quality performance results using a phantom to simulate chest computed radiography.

Authors:  Wilbroad Muhogora; Renato Padovani; Peter Msaki
Journal:  J Med Phys       Date:  2011-01

7.  The importance of radiation quality for optimisation in radiology.

Authors:  Cj Martin
Journal:  Biomed Imaging Interv J       Date:  2007-04-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.