Literature DB >> 16723771

A biphasic parameter estimation method for quantitative analysis of dynamic renal scintigraphic data.

T S Koh1, Jeff L Zhang, C K Ong, B Shuter.   

Abstract

Dynamic renal scintigraphy is an established method in nuclear medicine, commonly used for the assessment of renal function. In this paper, a biphasic model fitting method is proposed for simultaneous estimation of both vascular and parenchymal parameters from renal scintigraphic data. These parameters include the renal plasma flow, vascular and parenchymal mean transit times, and the glomerular extraction rate. Monte Carlo simulation was used to evaluate the stability and confidence of the parameter estimates obtained by the proposed biphasic method, before applying the method on actual patient study cases to compare with the conventional fitting approach and other established renal indices. The various parameter estimates obtained using the proposed method were found to be consistent with the respective pathologies of the study cases. The renal plasma flow and extraction rate estimated by the proposed method were in good agreement with those previously obtained using dynamic computed tomography and magnetic resonance imaging.

Entities:  

Mesh:

Year:  2006        PMID: 16723771     DOI: 10.1088/0031-9155/51/11/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Functional assessment of the kidney from magnetic resonance and computed tomography renography: impulse retention approach to a multicompartment model.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Lilach O Lerman; Qun Chen; Chekema Prince; Niels Oesingmann; Ting Song; Vivian S Lee
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

2.  Performance of an efficient image-registration algorithm in processing MR renography data.

Authors:  Christopher C Conlin; Jeff L Zhang; Florian Rousset; Clement Vachet; Yangyang Zhao; Kathryn A Morton; Kristi Carlston; Guido Gerig; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

Review 3.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

4.  Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis.

Authors:  Pierre-Hugues Vivier; Pippa Storey; Henry Rusinek; Jeff L Zhang; Akira Yamamoto; Kristopher Tantillo; Umer Khan; Ruth P Lim; James S Babb; Devon John; Lewis W Teperman; Hersh Chandarana; Kent Friedman; Judith A Benstein; Edward Y Skolnik; Vivian S Lee
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

Review 5.  Functional MRI of the kidneys.

Authors:  Jeff L Zhang; Henry Rusinek; Hersh Chandarana; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2013-02       Impact factor: 4.813

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.