Literature DB >> 16717082

Accuracy and precision of test weighing to assess milk intake in newborn infants.

O E M Savenije1, P L P Brand.   

Abstract

BACKGROUND: Test weighing is commonly used to estimate milk intake in newborn infants.
OBJECTIVE: To assess the accuracy and precision of test weighing in clinical practice.
METHODS: Infants fed by bottle, cup, or nasogastric tube were weighed before and immediately after feeding by a blinded investigator. Actual milk intake was determined by reading the millilitre scale of the milk container before and after feeding. The accuracy and precision of test weighing was assessed by examining the frequency distribution of the difference between weight change and actual milk intake.
RESULTS: Ninety four infants completed the study. The mean difference between weight change and actual milk intake was 1.3 ml, indicating good accuracy. The precision of test weighing, however, was poor: 95% of differences between weight change and actual milk intake ranged from -12.4 to 15 ml. The maximum difference was 30 ml. Imprecision was not influenced by the presence of monitor or oxygen saturation wires, intravenous lines, or vomiting of the infant.
CONCLUSIONS: Test weighing is an imprecise method for assessing milk intake in young infants. This is probably because infant weighing scales are not sensitive enough to pick up small changes in an infant's weight after feeding. Because of its unreliability, test weighing should not be used in clinical practice.

Entities:  

Mesh:

Year:  2006        PMID: 16717082      PMCID: PMC2672832          DOI: 10.1136/adc.2005.091876

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  13 in total

Review 1.  Assessment of infant feeding: the validity of measuring milk intake.

Authors:  Kelley S Scanlon; Maria P Alexander; Mary K Serdula; Margarett K Davis; Barbara A Bowman
Journal:  Nutr Rev       Date:  2002-08       Impact factor: 7.110

2.  Evaluation of test-weighing for the assessment of milk volume intake of formula-fed infants and its application to breast-fed infants.

Authors:  M W Borschel; A Kirksey; R E Hannemann
Journal:  Am J Clin Nutr       Date:  1986-03       Impact factor: 7.045

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Accuracy of single- and two-feed test weighing in assessing 24 h breast milk production.

Authors:  M C Neville; R Keller
Journal:  Early Hum Dev       Date:  1984-04       Impact factor: 2.079

5.  Validity of routine clinical test weighing as a measure of the intake of breast-fed infants.

Authors:  M F Whitfield; R Kay; S Stevens
Journal:  Arch Dis Child       Date:  1981-12       Impact factor: 3.791

6.  How accurate is clinical test weighing of the newborn?

Authors:  S Stevens; M F Whitfield
Journal:  Midwives Chron       Date:  1980-05

7.  The determination of short-term breast volume changes and the rate of synthesis of human milk using computerized breast measurement.

Authors:  S E Daly; J C Kent; D Q Huynh; R A Owens; B F Alexander; K C Ng; P E Hartmann
Journal:  Exp Physiol       Date:  1992-01       Impact factor: 2.969

8.  The accuracy of test weighing for preterm infants.

Authors:  P P Meier; T Y Lysakowski; J L Engstrom; K L Kavanaugh; H H Mangurten
Journal:  J Pediatr Gastroenterol Nutr       Date:  1990-01       Impact factor: 2.839

9.  Measurement of the milk intake of breast-fed infants.

Authors:  P G Arthur; P E Hartmann; M Smith
Journal:  J Pediatr Gastroenterol Nutr       Date:  1987 Sep-Oct       Impact factor: 2.839

10.  Indirect test weighing: a non-intrusive technique for estimating night-time breast milk intake.

Authors:  M W Woolridge; D A Jackson; S M Imong; Y Yootabootr; K Amatayakul
Journal:  Hum Nutr Clin Nutr       Date:  1987-09
View more
  6 in total

1.  Test weighing for term and premature infants is an accurate procedure.

Authors:  Paula P Meier; Janet L Engstrom
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-03       Impact factor: 5.747

2.  Test weighing for term and premature infants is an accurate procedure: author's reply.

Authors:  Paul L P Brand
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-07       Impact factor: 5.747

3.  Prevention of hypernatraemic dehydration in breastfed newborn infants by daily weighing.

Authors:  Gabriel Konetzny; Hans Ulrich Bucher; Romaine Arlettaz
Journal:  Eur J Pediatr       Date:  2008-09-26       Impact factor: 3.183

4.  Use of water turnover method to measure mother's milk flow in a rat model: Application to dams receiving a low protein diet during gestation and lactation.

Authors:  Thomas Sevrin; Marie-Cécile Alexandre-Gouabau; Dominique Darmaun; Antoine Palvadeau; Agnès André; Patrick Nguyen; Khadija Ouguerram; Clair-Yves Boquien
Journal:  PLoS One       Date:  2017-07-17       Impact factor: 3.240

5.  Effects of relaxation therapy on maternal psychological state, infant growth and gut microbiome: protocol for a randomised controlled trial investigating mother-infant signalling during lactation following late preterm and early term delivery.

Authors:  Jinyue Yu; Jonathan Wells; Zhuang Wei; Mary Fewtrell
Journal:  Int Breastfeed J       Date:  2019-12-16       Impact factor: 3.461

6.  Subclinical Mastitis in a European Multicenter Cohort: Prevalence, Impact on Human Milk (HM) Composition, and Association with Infant HM Intake and Growth.

Authors:  Tinu Mary Samuel; Carlos Antonio De Castro; Stephane Dubascoux; Michael Affolter; Francesca Giuffrida; Claude Billeaud; Jean-Charles Picaud; Massimo Agosti; Isam Al-Jashi; Almerinda Barroso Pereira; Maria Jose Costeira; Maria Gorett Silva; Giovanna Marchini; Thameur Rakza; Kirsti Haaland; Tom Stiris; Silvia-Maria Stoicescu; Cecilia Martínez-Costa; Mireilla Vanpee; Magnus Domellöf; Castañeda-Gutiérrez Euridice; Sagar Kiran Thakkar; Irma Silva-Zolezzi
Journal:  Nutrients       Date:  2019-12-30       Impact factor: 5.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.