Literature DB >> 16716616

Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain.

M Alecci1, S Romanzetti, J Kaffanke, A Celik, H P Wegener, N J Shah.   

Abstract

MRI is proving to be a very useful tool for sodium quantification in animal models of stroke, ischemia, and cancer. In this work, we present the practical design of a dual-frequency RF surface coil that provides (1)H and (23)Na images of the rat head at 4 T. The dual-frequency RF surface coil comprised of a large loop tuned to the (1)H frequency and a smaller co-planar loop tuned to the (23)Na frequency. The mutual coupling between the two loops was eliminated by the use of a trap circuit inserted in the smaller coil. This independent-loop design was versatile since it enabled a separate optimisation of the sensitivity and RF field distributions of the two coils. To allow for an easy extension of this simple double-tuned coil design to other frequencies (nuclei) and dimensions, we describe in detail the practical aspects of the workbench design and MRI testing using a phantom that mimics in vivo conditions. A comparison between our independent-loop, double-tuned coil and a single-tuned (23)Na coil of equal size obtained with a phantom matching in vivo conditions, showed a reduction of the (23)Na sensitivity (about 28 %) because of signal losses in the trap inductance. Typical congruent (1)H and (23)Na rat brain images showing good SNR ((23)Na: brain 7, ventricular cerebrospinal fluid 11) and spatial resolution ((23)Na: 1.25 x 1.25 x 5mm(3)) are also reported. The in vivo SNR values obtained with this coil were comparable to, if not better than, other contemporary designs in the literature.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16716616     DOI: 10.1016/j.jmr.2006.04.011

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  13 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  In vivo 31P MRS detection of an alkaline inorganic phosphate pool with short T1 in human resting skeletal muscle.

Authors:  H E Kan; D W J Klomp; C S Wong; V O Boer; A G Webb; P R Luijten; J A Jeneson
Journal:  NMR Biomed       Date:  2010-10       Impact factor: 4.044

3.  Sodium MR imaging detection of mild Alzheimer disease: preliminary study.

Authors:  E A Mellon; D T Pilkinton; C M Clark; M A Elliott; W R Witschey; A Borthakur; R Reddy
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

4.  A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-08

5.  A dual-tuned multichannel bilateral RF coil for 1 H/23 Na breast MRI at 7 T.

Authors:  Carlotta Ianniello; Guillaume Madelin; Linda Moy; Ryan Brown
Journal:  Magn Reson Med       Date:  2019-05-31       Impact factor: 4.668

6.  Trap Design and Construction for High-Power Multinuclear Magnetic Resonance Experiments.

Authors:  Joseph V Rispoli; Ivan E Dimitrov; Sergey Cheshkov; Craig Malloy; Steven M Wright; Mary P McDougall
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-11-17       Impact factor: 1.176

7.  1 H-13 C independently tuned radiofrequency surface coil applied for in vivo hyperpolarized MRI.

Authors:  Peng Cao; Xiaoliang Zhang; Ilwoo Park; Chloe Najac; Sarah J Nelson; Sabrina Ronen; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

Review 8.  High-performance radiofrequency coils for (23)Na MRI: brain and musculoskeletal applications.

Authors:  Graham C Wiggins; Ryan Brown; Karthik Lakshmanan
Journal:  NMR Biomed       Date:  2015-09-24       Impact factor: 4.044

9.  A 3 T sodium and proton composite array breast coil.

Authors:  Joshua D Kaggie; J Rock Hadley; James Badal; John R Campbell; Daniel J Park; Dennis L Parker; Glen Morrell; Rexford D Newbould; Ali F Wood; Neal K Bangerter
Journal:  Magn Reson Med       Date:  2013-09-16       Impact factor: 4.668

10.  Initial in vivo rodent sodium and proton MR imaging at 21.1 T.

Authors:  Victor D Schepkin; William W Brey; Peter L Gor'kov; Samuel C Grant
Journal:  Magn Reson Imaging       Date:  2010-01-04       Impact factor: 2.546