A robust method for estimating regional pulmonary parameters in presence of noise.

Richard A Guyer1, Michael D Hellman, Kiarash Emami, Stephen Kadlecek, Robert V Cadman, Jiangsheng Yu, Vahid Vadhat, Masaru Ishii, John MacDuffie Woodburn, Michelle Law, Rahim R Rizi.   

Abstract

RATIONALE AND
OBJECTIVES: Estimation of regional lung function parameters from hyperpolarized gas magnetic resonance images can be very sensitive to presence of noise. Clustering pixels and averaging over the resulting groups is an effective method for reducing the effects of noise in these images, commonly performed by grouping proximal pixels together, thus creating large groups called "bins." This method has several drawbacks, primarily that it can group dissimilar pixels together, and it degrades spatial resolution. This study presents an improved approach to simplifying data via principal component analysis (PCA) when noise level prohibits a pixel-by-pixel treatment of data, by clustering them based on similarity to one another rather than spatial proximity. The application to this technique is demonstrated in measurements of regional lung oxygen tension using hyperpolarized (3)He magnetic resonance imaging (MRI).
MATERIALS AND METHODS: A synthetic dataset was generated from an experimental set of oxygen tension measurements by treating the experimentally derived parameters as "true" values, and then solving backwards to generate "noiseless" images. Artificial noise was added to the synthetic data, and both traditional binning and PCA-based clustering were performed. For both methods, the root-mean-square (RMS) error between each pixel's "estimated" and "true" parameters was computed and the resulting effects were compared.
RESULTS: At high signal-to-noise ratios (SNRs), clustering did not enhance accuracy. Clustering did, however, improve parameter estimations for moderate SNR values (below 100). For SNR values between 100 and 20, the PCA-based K-means clustering analysis yielded greater accuracy than Cartesian binning. In extreme cases (SNR<5), Cartesian binning can be more accurate.
CONCLUSIONS: The reliability of parameters estimation in imaging-based regional functional measurements can be improved in the presence of noise by utilizing principal component analysis-based clustering without sacrificing spatial resolution compared to Cartesian binning. Results suggest that this approach has a great potential for robust grouping of pixels in hyperpolarized (3)He MRI maps of lung oxygen tension.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18486010      PMCID: PMC2430423          DOI: 10.1016/j.acra.2008.03.002

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  20 in total

1.  On clustering fMRI time series.

Authors:  C Goutte; P Toft; E Rostrup; F Nielsen; L K Hansen
Journal:  Neuroimage       Date:  1999-03       Impact factor: 6.556

2.  Fast formation of statistically reliable FDG parametric images based on clustering and principal components.

Authors:  Y Kimura; M Senda; N M Alpert
Journal:  Phys Med Biol       Date:  2002-02-07       Impact factor: 3.609

3.  Feature-space clustering for fMRI meta-analysis.

Authors:  C Goutte; L K Hansen; M G Liptrot; E Rostrup
Journal:  Hum Brain Mapp       Date:  2001-07       Impact factor: 5.038

4.  Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI.

Authors:  M C Fischer; Z Z Spector; M Ishii; J Yu; K Emami; M Itkin; R Rizi
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

5.  Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI.

Authors:  A J Deninger; B Eberle; M Ebert; T Grossmann; W Heil; H Kauczor; L Lauer; K Markstaller; E Otten; J Schmiedeskamp; W Schreiber; R Surkau; M Thelen; N Weiler
Journal:  J Magn Reson       Date:  1999-12       Impact factor: 2.229

Review 6.  The alliance of genes and environment in asthma and allergy.

Authors:  W Cookson
Journal:  Nature       Date:  1999-11-25       Impact factor: 49.962

7.  The Rician distribution of noisy MRI data.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

8.  Detection and localization of pulmonary air leaks using laser-polarized (3)He MRI.

Authors:  D A Roberts; R R Rizi; D A Lipson; M Aranda; J Baumgardner; L Bearn; J Hansen-Flaschen; W B Gefter; H H Hatabu; J S Leigh; M D Schnall
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

9.  Early emphysematous changes in asymptomatic smokers: detection with 3He MR imaging.

Authors:  Sean B Fain; Shilpa R Panth; Michael D Evans; Andrew L Wentland; James H Holmes; Frank R Korosec; Matthew J O'Brien; Harvey Fountaine; Thomas M Grist
Journal:  Radiology       Date:  2006-06       Impact factor: 11.105

10.  Quantitative measurement of regional lung ventilation using 3He MRI.

Authors:  Anselm J Deninger; Sven Månsson; J Stefan Petersson; Göran Pettersson; Peter Magnusson; Jonas Svensson; Björn Fridlund; Georg Hansson; Ingrid Erjefeldt; Per Wollmer; Klaes Golman
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

View more
  1 in total

1.  Comparison of single breath hyperpolarized 129 Xe MRI with dynamic 19 F MRI in cystic fibrosis lung disease.

Authors:  Andrew McCallister; Sang Hun Chung; Michael Antonacci; Margret Z Powell; Agathe S Ceppe; Scott H Donaldson; Yueh Z Lee; Rosa Tamara Branca; Jennifer L Goralski
Journal:  Magn Reson Med       Date:  2020-08-08       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.