Literature DB >> 16710664

Time-resolved contrast-enhanced magnetic resonance angiography of the hand with parallel imaging and view sharing: initial experience.

Katja Brauck1, Stefan Maderwald, Florian M Vogt, Michael Zenge, Jörg Barkhausen, Christoph U Herborn.   

Abstract

We sought to compare a three-dimensional, contrast-enhanced, magnetic resonance angiogram (3D CE MRA) sequence combining parallel-imaging (generalised autocalibrating partially parallel acquisitions (GRAPPA)) with a time-resolved echo-shared angiographic technique (TREAT) in an intraindividual comparison to a standard 3D MRA sequence. Four healthy volunteers (27-32 years), and 11 patients (11-82 years) with vascular pathologies of the hand were examined on a 1.5-Tesla (T) MR system (Magnetom Avanto, Siemens, Erlangen, Germany) using two multichannel receiver coils. Following automatic injection (flow rate 2.5 cc/s) of 0.1 mmol/kg gadoterate (Dotarem, Guerbet, Roissy, France), 32 consecutive 3D data sets were collected with the TREAT sequence (TR/TE: 4.02/1.31 ms, FA: 10 degrees, GRAPPA acceleration factor: R=2, TREAT factor: 5, voxel size: 1.0 x 0.7 x 1.3 mm(3)) and a T1-wwighted 3D gradient-echo sequence (TR/TE: 5.3/1.57 ms, FA: 30 degrees, GRAPPA acceleration factor: 2, voxel size: 0.71 x 0.71 x 0.71 mm(3,)). MR data sets were evaluated and compared for image quality and visualisation of vascular details. In the volunteer group, all MR imaging was successful while technical problems prevented acquisition of the standard protocol in two patients. For the corresponding segments, the number of visible segments was equal on both sequences. Overall image quality was significantly better on the standard protocol than on the TREAT protocol. TREAT MRA provided functional information in lesions with rapid blood flow, e.g. detection of feeding and draining vessels in an haemangioma. TREAT-MRA is a robust technique that combines morphological and functional information of the hand vasculature and deals with the very special physiological demands of vascular lesions, such as quick arteriovenous transit time.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16710664     DOI: 10.1007/s00330-006-0275-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  11 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Optimization of contrast-enhanced MR angiography of the hands with a timing bolus and elliptically reordered 3D pulse sequence.

Authors:  J T Winterer; K Scheffler; G Paul; M Hauer; O Schäfer; C Altehoefer; J Laubenberger
Journal:  J Comput Assist Tomogr       Date:  2000 Nov-Dec       Impact factor: 1.826

3.  Contrast-enhanced MR angiography and perfusion imaging of the hand.

Authors:  J W Goldfarb; M G Hochman; D S Kim; R R Edelman
Journal:  AJR Am J Roentgenol       Date:  2001-11       Impact factor: 3.959

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the chest: combination of parallel imaging with view sharing (TREAT).

Authors:  Christian Fink; Sebastian Ley; Randall Kroeker; Martin Requardt; Hans-Ulrich Kauczor; Michael Bock
Journal:  Invest Radiol       Date:  2005-01       Impact factor: 6.016

Review 6.  Magnetic resonance angiography of the hand. A review.

Authors:  V S Lee; H M Lee; N M Rofsky
Journal:  Invest Radiol       Date:  1998-09       Impact factor: 6.016

7.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

Review 8.  Contrast-enhanced MR angiography of the hand.

Authors:  David A Connell; George Koulouris; Duncan A Thorn; Hollis G Potter
Journal:  Radiographics       Date:  2002 May-Jun       Impact factor: 5.333

Review 9.  MR angiography of the hand and wrist.

Authors:  N M Rofsky
Journal:  Magn Reson Imaging Clin N Am       Date:  1995-05       Impact factor: 2.266

10.  High resolution contrast enhanced MR-angiography of the hand arteries: preliminary experiences.

Authors:  U Krause; T Pabst; W Kenn; D Hahn
Journal:  Vasa       Date:  2002-08       Impact factor: 1.961

View more
  10 in total

1.  Bilateral contrast-enhanced MR angiography of the hand: diagnostic image quality of accelerated MRI using echo sharing with interleaved stochastic trajectories (TWIST).

Authors:  Jan Thorsten Winterer; P Blanke; A Schaefer; G Pache; M Langer; M Markl
Journal:  Eur Radiol       Date:  2010-11-18       Impact factor: 5.315

2.  Bilateral ce-MR angiography of the hands at 3.0 T and 1.5 T: intraindividual comparison of quantitative and qualitative image parameters in healthy volunteers.

Authors:  Jan Thorsten Winterer; Olaf Moske-Eick; Michael Markl; Alexander Frydrychowicz; Thorsten Alexander Bley; Mathias Langer
Journal:  Eur Radiol       Date:  2007-11-27       Impact factor: 5.315

3.  Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience.

Authors:  Ruth P Lim; Pippa Storey; Iliyana P Atanasova; Jian Xu; Elizabeth M Hecht; James S Babb; David R Stoffel; Hugo Chang; Kellyanne McGorty; Qun Chen; Henry Rusinek; H Michael Belmont; Vivian S Lee
Journal:  Radiology       Date:  2009-06-30       Impact factor: 11.105

Review 4.  Assessment of vascular disorders of the upper extremity with contrast-enhanced magnetic resonance angiography: pictorial review.

Authors:  Ahmed A K A Razek; Ehab Saad; Nermin Soliman; Heba A Elatta
Journal:  Jpn J Radiol       Date:  2010-02-26       Impact factor: 2.374

5.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

6.  Noncontrast magnetic resonance angiography of the hand: improved arterial conspicuity by multidirectional flow-sensitive dephasing magnetization preparation in 3D balanced steady-state free precession imaging.

Authors:  Zhaoyang Fan; Philip A Hodnett; Amir H Davarpanah; Timothy G Scanlon; John J Sheehan; John Varga; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2011-08       Impact factor: 6.016

Review 7.  High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet.

Authors:  Clifton R Haider; Stephen J Riederer; Eric A Borisch; James F Glockner; Roger C Grimm; Thomas C Hulshizer; Thanila A Macedo; Petrice M Mostardi; Phillip J Rossman; Terri J Vrtiska; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2011-07       Impact factor: 4.813

8.  Ferumoxytol-enhanced MR Venography of the Central Veins of the Thorax for the Evaluation of Stenosis and Occlusion in Patients with Renal Impairment.

Authors:  Christopher J R Gallo; Joseph G Mammarappallil; David Y Johnson; Hamid Chalian; James Ronald; Mustafa R Bashir; Charles Y Kim
Journal:  Radiol Cardiothorac Imaging       Date:  2020-11-19

9.  Preoperative MRI Evaluation of Hand Vessels in Children With Congenital Syndactyly Malformation by a Contrast-Enhanced Three-Dimensional Water-Selective Cartilage Scan.

Authors:  Bo Liu; Jinhua Cai; Xiaofei Tian; Kaiping Huang; Daisong Liu; Helin Zheng; Longlun Wang; Jing Yang; Hongrong Xu
Journal:  Front Pediatr       Date:  2022-04-06       Impact factor: 3.569

10.  Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography.

Authors:  Eric G Stinson; Eric A Borisch; Casey P Johnson; Joshua D Trzasko; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2013-07-29       Impact factor: 4.813

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.