Literature DB >> 16699751

Does 16-MDCT angiography scanning direction affect image quality of coronary artery bypass grafts and the native coronary arteries?

Tuncay Hazirolan1, Baris Turkbey, Musturay Karcaaltincaba, Deniz Akata, Levent Sahiner, Kudret Aytemir, M Ali Oto, Ferhun Balkanci, Aytekin Besim.   

Abstract

To assess the impact of scanning direction on the image quality of coronary artery bypass grafts (CABGs), native coronary arteries (NCAs) were examined by electrocardiographically (ECG) gated 16-row multidetector computed tomography (16-MDCT). Eighty-two patients with 209 grafts were studied by 16-MDCT. Forty-one patients with 111 grafts were scanned craniocaudally. Forty-one patients with 98 grafts were scanned caudocranially. CABG, native coronary arteries were examined in four (proximal, middle, distal, distal anastomoses), three (proximal, middle, distal) segments, respectively. Subjective image quality on a four-point scale was calculated for segments. Scores of groups were compared. Results Image quality scores of proximal, distal segments of the right coronary artery (RCA) were better in caudocranially scanned group (P<0.05). When we subgrouped patients according to initial heart rates (IHR) (group 1, <65 beats/min; group 2, > or =65 beats/min), there was no statistical significance between image quality scores of coronary arteries, CABG when IHR was <65 beats/min in groups regardless of scanning direction. Scores of anastomotic segment of CABG to RCA, middle segments of circumflex coronary artery, proximal and distal segments of RCA in caudocranially scanned group were better when the IHR is > or =65 beats/min compared with the craniocaudally scanned group. When the IHR of the patient is > or =65 beats/min, performing ECG-gated 16-MDCT angiography in the caudocranial direction provides better image quality for evaluation of coronary arteries and CABGs.

Entities:  

Mesh:

Year:  2006        PMID: 16699751     DOI: 10.1007/s00330-006-0290-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  27 in total

1.  ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality.

Authors:  C Hong; C R Becker; A Huber; U J Schoepf; B Ohnesorge; A Knez; R Brüning; M F Reiser
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

Review 2.  Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography.

Authors:  Hyun Seok Choi; Byoung Wook Choi; Kyu Ok Choe; Donghoon Choi; Kyung-Jong Yoo; Myoung-In Kim; Jinna Kim
Journal:  Radiographics       Date:  2004 May-Jun       Impact factor: 5.333

3.  Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography.

Authors:  Marc Dewey; Alexander Lembcke; Christian Enzweiler; Bernd Hamm; Patrik Rogalla
Journal:  Ann Thorac Surg       Date:  2004-03       Impact factor: 4.330

4.  Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Authors:  Xavier L Hamoir; Thomas Flohr; Vincent Hamoir; Laurent Labaki; Jean-Yves Tricquet; Alain Duhamel; Jacques Kirsch
Journal:  Eur Radiol       Date:  2004-11-24       Impact factor: 5.315

5.  Coronary magnetic resonance angiography for the detection of coronary stenoses.

Authors:  W Y Kim; P G Danias; M Stuber; S D Flamm; S Plein; E Nagel; S E Langerak; O M Weber; E M Pedersen; M Schmidt; R M Botnar; W J Manning
Journal:  N Engl J Med       Date:  2001-12-27       Impact factor: 91.245

6.  Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification.

Authors:  M B Hofman; S A Wickline; C H Lorenz
Journal:  J Magn Reson Imaging       Date:  1998 May-Jun       Impact factor: 4.813

7.  Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography.

Authors:  Y Wang; E Vidan; G W Bergman
Journal:  Radiology       Date:  1999-12       Impact factor: 11.105

8.  Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

9.  Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery.

Authors:  L Campeau; M Enjalbert; J Lespérance; C Vaislic; C M Grondin; M G Bourassa
Journal:  Circulation       Date:  1983-09       Impact factor: 29.690

10.  Coronary bypass surgery with internal-thoracic-artery grafts--effects on survival over a 15-year period.

Authors:  A Cameron; K B Davis; G Green; H V Schaff
Journal:  N Engl J Med       Date:  1996-01-25       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.