Literature DB >> 9626870

Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification.

M B Hofman1, S A Wickline, C H Lorenz.   

Abstract

Motion of the coronary arteries during the heart cycle can result in image blurring and inaccurate flow quantification by MR. This condition applies particularly for longer acquisition windows that are typical of breath-hold coronary flow measurements. To determine the sensitivity of the technique to in-plane motion of different coronary arteries, the temporal variation in coronary position was measured in a plane perpendicular to the proximal portion of the vessel. The results indicated the presence of substantial displacement of the coronary arteries within the cardiac cycle, with a magnitude of motion approximately twice as large for the right as for the left coronary arteries. An estimation of the resulting vessel blurring was calculated, showing that the duration of the acquisition window for high spatial resolution coronary flow acquisitions should be less than 25 to 120 msec, depending on the specific coronary artery studied. In addition, these data specify optimal acquisition window placement for high resolution coronary angiography.

Entities:  

Mesh:

Year:  1998        PMID: 9626870     DOI: 10.1002/jmri.1880080309

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  30 in total

Review 1.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

2.  Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT.

Authors:  Antoine Hutt; Alain Duhamel; Valérie Deken; Jean-Baptiste Faivre; Francesco Molinari; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2015-09-04       Impact factor: 5.315

3.  Black-blood steady-state free precession (SSFP) coronary wall MRI for cardiac allografts: a feasibility study.

Authors:  Kai Lin; Xiaoming Bi; Ying Liu; Kirsi Taimen; Biao Lu; Debiao Li; James Carr
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

4.  Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit.

Authors:  Marcel J W Greuter; Joost Dorgelo; Wim G J Tukker; Matthijs Oudkerk
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

Review 5.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

6.  MR-based coronary artery blood velocity measurements in patients without coronary artery disease.

Authors:  M Schiemann; F Bakhtiary; V Hietschold; A Koch; A Esmaeili; H Ackermann; A Moritz; T J Vogl; N D Abolmaali
Journal:  Eur Radiol       Date:  2006-01-13       Impact factor: 5.315

7.  Coronary MR angiography at 3T during diastole and systole.

Authors:  Ahmed M Gharib; Daniel A Herzka; Ali O Ustun; Milind Y Desai; Julia Locklin; Roderic I Pettigrew; Matthias Stuber
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

8.  Displacement and velocity of the coronary arteries: cardiac and respiratory motion.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

9.  Impact of alcohol septal ablation on left anterior descending coronary artery blood flow in hypertrophic obstructive cardiomyopathy.

Authors:  Willem G van Dockum; Paul Knaapen; Mark B M Hofman; Joost P A Kuijer; Folkert J ten Cate; Jurrien M ten Berg; Aernout M Beek; Jos W R Twisk; Albert C van Rossum
Journal:  Int J Cardiovasc Imaging       Date:  2009-02-22       Impact factor: 2.357

10.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.