A novel approach to accurate portal dosimetry using CCD-camera based EPIDs.

E M Franken1, J C J de Boer, B J M Heijmen.   

Abstract

A new method for portal dosimetry using CCD camera-based electronic portal imaging devices (CEPIDs) is demonstrated. Unlike previous approaches, it is not based on a priori assumptions concerning CEPID cross-talk characteristics. In this method, the nonsymmetrical and position-dependent cross-talk is determined by directly imaging a set of cross-talk kernels generated by small fields ("pencil beams") exploiting the high signal-to-noise ratio of a cooled CCD camera. Signal calibration is achieved by imaging two reference fields. Next, portal dose images (PDIs) can be derived from electronic portal dose images (EPIs), in a fast forward-calculating iterative deconvolution. To test the accuracy of these EPI-based PDIs, a comparison is made to PDIs obtained by scanning diode measurements. The method proved accurate to within 0.2+/-0.7% (1 SD), for on-axis symmetrical and asymmetrical fields with different field widths and homogeneous phantom thicknesses, off-axis Alderson thorax fields and a strongly modulated IMRT field. Hence, the proposed method allows for fast, accurate portal dosimetry. In addition, it is demonstrated that the CEPID cross-talk signal is not only induced by optical photon reflection and scatter within the CEPID structure, but also by high-energy back-scattered radiation from CEPID elements (mirror and housing) towards the fluorescent screen.

Mesh:

Year:  2006        PMID: 16696464     DOI: 10.1118/1.2172746

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  In patient dose reconstruction using a cine acquisition for dynamic arc radiation therapy.

Authors:  Angelo Piermattei; Andrea Fidanzio; Luigi Azario; Francesca Greco; Alessandra Mameli; Savino Cilla; Luca Grimaldi; Guido D'Onofrio; Boris Giuseppe Augelli; Gerardina Stimato; Diego Gaudino; Sara Ramella; Rolando D'Angelillo; Francesco Cellini; Lucio Trodella
Journal:  Med Biol Eng Comput       Date:  2009-02-17       Impact factor: 2.602

2.  Accurate IMRT fluence verification for prostate cancer patients using 'in-vivo' measured EPID images and in-room acquired kilovoltage cone-beam CT scans.

Authors:  Ali Sam Ali; Maarten L P Dirkx; Ruud M Cools; Ben J M Heijmen
Journal:  Radiat Oncol       Date:  2013-09-10       Impact factor: 3.481

3.  Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry.

Authors:  Vahideh Nazari; Seied R Mahdavi; Ahmad Mostaar; Hassan Nedaei; Mohammad A Mosleh Shirazi; Alireza Nikoofar; Golbarg Esmailie
Journal:  J Med Signals Sens       Date:  2017 Jan-Mar
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.